Contents 558F180-210 559F180-216 558F300 558F240 559F240-300 FEATURES/BENEFITSEASY MAINTENANCE AND INSTALLATION 551B036-072 558F036-073 551B090-150 551A155,180558F090-150Totally Enclosed Condenser Fan Motors and permanently Single-Point Electrical Power Connections permit easierSERVICEABILITY QUIET, EFFICIENT OPERATION AND DEPENDABLE PERFORMANCE558F180-300 TABLE OF CONTENTSGuide Specifications - Sizes 558F036-1502. Some options may increase product lead times OPTIONS AND ACCESSORIESOPTIONS AND ACCESSORIES cont BAROMETRIC RELIEF/POWER EXHAUST 155-300 ShownLOW AMBIENT CONTROLS Dura-Shield Option DURA-SHIELD CONDENSER COIL OPTIONSCONDENSER COIL PROTECTION APPLICATIONS Perfect Humidity DEHUMIDIFICATION PACKAGEBRYANT COMMERCIAL THERMOSTAT LIGHT COMMERCIAL THERMIDISTATTIME GUARD CONTROL DURABLADE ECONOMIZERUNIT-MOUNTED DISCONNECT Sizes CONVENIENCE OUTLETFactory-installed, internally-mounted, NEC National Electri- cal Code and UL Underwriters’ Laboratories approved non-fused switch provides unit power shutoff with disconnect lockout protection capability. The switch is accessible from outside the unit COMPRESSOR HINGED PANEL OPTION 581B090-150 UNITS SHOWN HAIL GUARDCOIL GUARD GRILLE 036-150 Only CONTROL BOX HINGED PANEL OPTION 581B036-072 UNITS581B036-072 EVAPORATOR-FAN HINGED PANEL OPTIONFILTER HINGED PANEL OPTION LP CONVERSION KITCONTROLS OPERATING SEQUENCE - SIZE 036-073 UNITSOPERATING SEQUENCE - SIZE 090-150 UNITS SEQUENCE OF OPERATION SIZES CONTROLS contPerfect Humidity Dehumidification Option TYPICAL WIRING SCHEMATIC Single Fan Units, Sizes TYPICAL WIRING SCHEMATIC Two-Fan Units, Size EconoMi$erACTUATOR TYPICAL WIRING SCHEMATIC Sizes 3. Jumpers are omitted when unit is equipped with EconoMi$er TYPICAL WIRING SCHEMATIC cont EconoMi$er WiringNon-Fused Disconnect Optional TYPICAL PIPING AND WIRING - SIZES Vertical Discharge DuctingHorizontal Discharge Ducting 2. Installation must comply with all applicable codes Concentric Duct Distribution Unit Sizes APPLICATION DATA10. MAXIMUM OPERATING OUTDOOR-AIR TEMPERATURE 12. PERFECT HUMIDITY DEHUMIDIFICATION PACKAGEAPPLICATION DATA cont Applicationsc. MUSEUMS AND LIBRARIES - Humidity can damage books and artwork 15. PERFECT HUMIDITY DEHUMIDIFICATION PACKAGE FEATURES AND BENEFITS Pressure Enthalpy Curve db - Dry Bulb wb - Wet Bulb Psychrometric Chart 551B072 ShownWithout Subcooler Point 3 - Leaving Air F 63.0 db/56.8 wb With Subcooler558F E X 090 000 KB MODEL NUMBER NOMENCLATURE - 558F558F036 ARI* CAPACITY RATINGS558F036 PHYSICAL DATA - 558F036-073558F036 PHYSICAL DATA - 558F090-150558F036-150 BASE UNIT DIMENSIONS - 558F036-072BASE UNIT DIMENSIONS - 558F073 558F036-150 BASE UNIT DIMENSIONS - 558F090,102,120,150BASE UNIT DIMENSIONS - 558F091,121 ACCESSORY DIMENSIONS ACCESSORY DIMENSIONS cont III SELECT ELECTRIC HEAT SELECTION PROCEDURE with 558F048 exampleI DETERMINE COOLING AND HEATING REQUIRE- MENTS AT DESIGN CONDITIONS II SELECT UNIT BASED ON REQUIRED COOLING CAPACITYPERFORMANCE DATA COOLING CAPACITIESover COOLING CAPACITIES cont PERFORMANCE DATA cont558F036-150 PERFORMANCE DATA contCOOLING CAPACITIES cont over FAN PERFORMANCE - VERTICAL DISCHARGE UNITS FAN PERFORMANCE - VERTICAL DISCHARGE UNITS cont 558F036-150 PERFORMANCE DATA contFAN PERFORMANCE - VERTICAL DISCHARGE UNITS cont PERFORMANCE DATA cont 558F036-150FAN PERFORMANCE - VERTICAL DISCHARGE UNITS cont 558F036-150 PERFORMANCE DATA contFAN PERFORMANCE - VERTICAL DISCHARGE UNITS cont PERFORMANCE DATA cont 558F036-150FAN PERFORMANCE - VERTICAL DISCHARGE UNITS cont 558F036-150 PERFORMANCE DATA contFAN PERFORMANCE - VERTICAL DISCHARGE UNITS cont PERFORMANCE DATA cont 558F036-150FAN PERFORMANCE - VERTICAL DISCHARGE UNITS cont 558F036-150 PERFORMANCE DATA contFAN PERFORMANCE - VERTICAL DISCHARGE UNITS cont PERFORMANCE DATA cont FAN PERFORMANCE - HORIZONTAL DISCHARGE UNITS FAN PERFORMANCE - HORIZONTAL DISCHARGE UNITS cont 558F036-150 PERFORMANCE DATA contFAN PERFORMANCE - HORIZONTAL DISCHARGE UNITS cont PERFORMANCE DATA cont 558F036-150FAN PERFORMANCE - HORIZONTAL DISCHARGE UNITS cont 558F036-150 PERFORMANCE DATA contFAN PERFORMANCE - HORIZONTAL DISCHARGE UNITS cont PERFORMANCE DATA cont 558F036-150FAN PERFORMANCE - HORIZONTAL DISCHARGE UNITS cont 558F036-150 PERFORMANCE DATA contFAN PERFORMANCE - HORIZONTAL DISCHARGE UNITS cont PERFORMANCE DATA cont 558F036-150FAN PERFORMANCE - HORIZONTAL DISCHARGE UNITS cont 558F036-150 PERFORMANCE DATA contFAN PERFORMANCE - HORIZONTAL DISCHARGE UNITS cont PERFORMANCE DATA cont 4. Interpolation is permissible. Do not extrapolate GENERAL FAN PERFORMANCE NOTESACCESSORY/FIOP STATIC PRESSURE in. wg - 558F036-073 ACCESSORY/FIOP STATIC PRESSURE* in. wg - 558F090-150FAN RPM AT MOTOR PULLEY SETTINGS EVAPORATOR-FAN MOTOR EFFICIENCY EconoMi$er Power Exhaust Performance 558F036-073EconoMi$er Power Exhaust Performance 558F090-150 OUTDOOR SOUND DATA Total UnitCONTINUOUS BHP EVAPORATOR-FAN MOTOR PERFORMANCEMULTIPLICATION FACTORS ELECTRIC HEATING CAPACITIESELECTRICAL DATA - 558F036-073 ELECTRICAL DATA - 558F036-073 cont ELECTRICAL DATA - 558F036-073 cont ELECTRICAL DATA - 558F090-150 ELECTRICAL DATA - 558F090-150 cont 2. Unbalanced 3-Phase Supply Voltage LEGEND AND NOTES FOR ELECTRICAL DATA TABLES PAGESMODEL NUMBER NOMENCLATURE - 551B 551B036-150551B E X 090 000 DA PHYSICAL DATA - 551B036-072 PHYSICAL DATA - 551B090-150 High Efficiency Enhanced Copper Tubes, Aluminum Double-Wavy FinsAcutrol Metering Device BASE UNIT DIMENSIONS - 551B036-072 551B036551B036-150 BASE UNIT DIMENSIONS - 551B090-150ACCESSORY DIMENSIONS - 551B036-072 ACCESSORY DIMENSIONS - 551B090-150 SELECTION PROCEDURE With 551B048 Example IV DETERMINE FAN SPEED AND POWER REQUIRE- MENTS AT DESIGN CONDITIONSV DETERMINE NET CAPACITIES COOLING CAPACITIES, STANDARD UNITS tldb = tedbhlwb = hewb 551B036 COOLING CAPACITIES, STANDARD UNITS cont551B036 COOLING CAPACITIES, UNITS WITH PERFECT HUMIDITY OPTION 551B036 COOLING CAPACITIES, UNITS WITH PERFECT HUMIDITY OPTION contPERFORMANCE DATA CONT 551B036 551B036 FAN PERFORMANCE - VERTICAL DISCHARGE UNITS cont PERFORMANCE DATA contFAN PERFORMANCE - VERTICAL DISCHARGE UNITS cont PERFORMANCE DATA contFAN PERFORMANCE - HORIZONTAL DISCHARGE UNITS PERFORMANCE DATA cont551B036-150 PERFORMANCE DATA contFAN PERFORMANCE - HORIZONTAL DISCHARGE UNITS cont PERFORMANCE DATA cont 551B036-150FAN PERFORMANCE - HORIZONTAL DISCHARGE UNITS cont FAN PERFORMANCE - HORIZONTAL DISCHARGE UNITS cont FAN RPM AT MOTOR PULLEY SETTING* STANDARD MOTOR/DRIVE FAN RPM AT MOTOR PULLEY SETTING* HIGH-STATIC MOTOR/DRIVEEVAPORATOR-FAN MOTOR PERFORMANCE - STANDARD MOTOR ELECTRIC HEATERS STATIC PRESSURE DROP in. wg 551B090-150 ACCESSORY/FIOP ECONOMIZERS ANDEVAPORATOR-FAN MOTOR PERFORMANCE - HIGH-STATIC MOTORS ELECTRIC HEATERS STATIC PRESSURE DROP in. wg 551B036-072EconoMi$er Power Exhaust Performance 551B036-072 Vertical EconoMi$er Barometric Relief Damper CharacteristicsHorizontal EconoMi$er Barometric Relief Damper Characteristics EconoMi$er Power Exhaust PerformanceHorizontal EconoMi$er Return-Air Pressure Drop OUTDOOR SOUND POWER TOTAL UNITVertical EconoMi$er Outdoor-Air Leakage Vertical EconoMi$er Return-Air Pressure DropLEGEND AND NOTES FOR ELECTRICAL DATA TABLES STANDARD MOTOR UNITS WITHOUT ELECTRICAL CONVENIENCE OUTLET ELECTRICAL DATASTANDARD MOTOR UNITS WITHOUT ELECTRICAL CONVENIENCE OUTLET cont ELECTRICAL DATA contSTANDARD MOTOR UNITS WITH ELECTRICAL CONVENIENCE OUTLET STANDARD MOTOR UNITS WITH ELECTRICAL CONVENIENCE OUTLET cont HIGH-STATIC MOTOR UNITS WITHOUT ELECTRICAL CONVENIENCE OUTLET 551B120†† HIGH-STATIC MOTOR UNITS WITHOUT ELECTRICAL CONVENIENCE OUTLET cont551B090†† 551B102††HIGH-STATIC MOTOR UNITS WITH ELECTRICAL CONVENIENCE OUTLET HIGH-STATIC MOTOR UNITS WITH ELECTRICAL CONVENIENCE OUTLET cont PART 2 - PRODUCTS GUIDE SPECIFICATIONS - SIZES558F/551B036-150 PART 1 - GENERALGUIDE SPECIFICATIONS - SIZES 036-150 cont 13. High-Static Motor and Drive 036-120 3-phase units only LOW OUTDOOR TEMPERATURE OPERATING LIMITS F MODEL NUMBER NOMENCLATURE - 559F5 5 9 F E X 1 8 0 0 0 0 A H C B AIR QUANTITY LIMITS559F180-300 ARI* CAPACITY RATINGS contELECTRIC RESISTANCE HEATER DATA - 559F180-300 PHYSICAL DATA - 559F180-300 Aluminum Pre-Coated, or Copper Plate FinsCopper Plate Fins, Face Split OPERATING AND RIGGING WEIGHTS OPTIONS AND ACCESSORIES Weight AddersPHYSICAL DATA - 559F180-300 cont 300-559F180 BASE UNIT DIMENSIONS - 559F180-216BASE UNIT DIMENSIONS - 559F240-300 DIMENSIONS degrees and inches Horizontal and Vertical Roof Curbs and Horizontal Adapter CurbBarometric Relief/Power Exhaust Horizontal Supply/Return Adapter InstallationFactory-Installed Convenience Outlet Factory-Installed Non-Fused DisconnectK.O. - Knockout IV DETERMINE NET COOLING CAPACITY SELECTION PROCEDURE with 559F180 exampleIII DETERMINE FAN SPEED AND POWER REQUIRE- MENTS AT DESIGN CONDITIONS I DETERMINE COOLING REQUIREMENTS AT DESIGN CONDITIONSover over Above 80 F edb, add corr factor x cfm to SHC hlwb = 559F180tldb tlwb =FAN PERFORMANCE - 559F180-300 UNITS GLYCOL HEATING PERFORMANCEFAN PERFORMANCE - 559F180-300 UNITS cont 559F180OUTDOOR SOUND POWER ACCESSORY/FIOP STATIC PRESSURE in. wg* - 559F180ACCESSORY/FIOP STATIC PRESSURE in. wg* - 559F216-300 Fan Performance Using Accessory Power Exhaust 559F180-300 Horizontal Supply/Return Fan Performance with CRRFCURB013A00High Static Regain Adapter 20 Tons 3 Ph, 60 Hz559F180-300 MODEL NUMBER NOMENCLATURE - 558F180-300 558F180-3005 5 8 F E X 2 1 0 0 0 0 A A A A 3750 ELECTRIC RESISTANCE HEATER DATA - 558F180-300558F180 PHYSICAL DATA - 558F180-300PHYSICAL DATA - 558F180-300 cont BASE UNIT DIMENSIONS - 558F180 558F180 BASE UNIT DIMENSIONS - 558F240BASE UNIT DIMENSIONS - 558F300 Side supply and Standard curbStandard curb for units requiringHorizontal Adapter PACKAGE NO2 ′-0 ″ Pre-Assembled, High Static558F180-300 SELECTION PROCEDURE with 558F240 Example PERFORMANCE DATA cont COOLING CAPACITIES LEGEND AND NOTES This accessory glycol coil is intended for use with a MINIMUM of 25% glycol 558F180 FAN PERFORMANCE - 558F180-300 UNITSFAN PERFORMANCE - 558F180-300 UNITS cont ACCESSORY/FIOP STATIC PRESSURE in. wg* - 558F180-300 Fan Performance Using Accessory Power Exhaust 558F180-300 ELECTRICAL DATA - 558F180-300 ELECTRICAL DATA - 558F180-300 cont COOLING OPERATION AIR QUANTITY LIMITS MODEL NUMBER NOMENCLATURE - 551A551A155-180 551A E X 155 000 AJ C BINDOOR SOUND DATA TOTAL UNIT ELECTRIC RESISTANCE HEATER DATAFace Split PHYSICAL DATA - 551A155,180OPTIONS AND ACCESSORIES PHYSICAL DATA contWeight Adders BASE UNIT DIMENSIONS - 551A155,180 551A155-180 ACCESSORY DIMENSIONS551A155-180 ACCESSORY DIMENSIONS contHorizontal Supply/Return Adapter Installation Barometric Relief/Power Exhaust551A155-180 SELECTION PROCEDURE VI SELECT THE UNIT THAT CORRESPONDS TO POWER SOURCE AVAILABLEV DETERMINE NET COOLING CAPACITIES BYPASS ENTERING AIR DRY-BULB TEMP FFACTOR FACTOR ENTERING AIR DRY-BULB TEMP F551A155 under551A155 FAN PERFORMANCE - 551A155,180 UNITSFAN PERFORMANCE - 551A155,180 UNITS cont ACCESSORY/FIOP STATIC PRESSURE in. wg - 551A155,180 UNITS ACCESSORY/FIOP STATIC PRESSURE in. wg* - 551A155,180EVAPORATOR FAN MOTOR PERFORMANCE Fan Performance Using Accessory Power Exhaust 551A155,180551A155 ELECTRICAL DATA - 551A155,180551A/558F/559F155-300 gas passing through motor windings and shall have GUIDE SPECIFICTIONS - SIZES 155-300 cont1. Unit shall be capable of starting and running at 125 F ambient outdoor temperature per maximum load criGUIDE SPECIFICATIONS - SIZES 155-300 cont 551A/558F/559F155-300 50-60 INDEX21-25 89-92Printed in U.S.A SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICEUNIT MUST BE INSTALLED IN ACCORDANCE WITH INSTALLATION INSTRUCTIONS Copyright 2002 Bryant Heating & Cooling Systems
Related manuals
Manual 36 pages 40.32 Kb Manual 52 pages 34.7 Kb Manual 61 pages 53.59 Kb Manual 70 pages 22.19 Kb

551A, 551B, 558F specifications

The Bryant 551B and 551C are two highly efficient air conditioning units designed to provide optimal comfort in residential settings. Known for their reliability and performance, these models are part of Bryant's esteemed line of heating and cooling solutions.

One of the standout features of the Bryant 551B is its two-stage cooling system, which allows for better humidity control and increased comfort. This ensures that homeowners can enjoy consistent temperatures while reducing energy consumption. The unit operates quietly, thanks to its noise-reducing technology, making it an ideal choice for bedrooms and living spaces.

On the other hand, the Bryant 551C builds upon this foundation with its variable-speed compressor. This technology allows the unit to adjust its cooling output according to the specific needs of the home. This results in seamless operation and even greater energy efficiency. Both models also incorporate Bryant's advanced control capabilities, which allow users to monitor and adjust settings remotely via smart devices, adding a layer of convenience and modernity to home climate control.

With an emphasis on durability, both the 551B and 551C feature a galvanized steel cabinet that protects against weather-related damage. The powder coat finish further enhances their resistance to rust and corrosion, ensuring a long lifespan and minimal maintenance.

Another significant characteristic of these units is their excellent Seasonal Energy Efficiency Ratio (SEER) ratings. The 551B boasts a SEER rating of up to 16, while the 551C takes it even further with ratings exceeding 20. This efficiency not only translates to lower energy bills for homeowners but also contributes to a reduced carbon footprint, making these units environmentally friendly options.

Both models are also designed to operate with eco-friendly refrigerants, aligning with modern energy standards and regulations aimed at reducing greenhouse gas emissions.

In summary, the Bryant 551B and 551C are exemplary choices for homeowners looking for reliable, efficient, and high-performing air conditioning solutions. With features such as two-stage and variable-speed compressors, advanced smart technology, and robust construction, these models stand out in the competitive HVAC market. They promise a comfortable indoor environment along with significant energy savings, making them a wise investment for the future.