DeWalt A08184 instruction manual Know Your Air Compressor, Description of Operation

Page 12
Drain Valve

OPERATION

Know Your Air Compressor

READ THIS OWNER’S MANUAL AND SAFETY RULES YOUR UNIT. Compare the illustrations with your unit to the location of various controls and adjustments. Save reference.

BEFORE OPERATING familiarize yourself with this manual for future

Description of Operation

Become familiar with these controls before operating the unit.

On/Auto/Off Switch: Turn this switch "ON/AUTO" to provide automatic power to the pressure switch and "OFF" to remove power at the end of each use.

Pressure

Tank Pressure Gauge

Outlet

Switch

 

Pressure

 

 

Gauge

Pressure Switch: The pressure

 

 

switch automatically starts the

 

 

motor when the air tank pressure

 

 

drops below the factory set

 

 

"cut-in" pressure. It stops the

 

 

motor when the air tank pressure

 

 

reaches the factory set "cut-out"

 

Regulator

pressure.

On/Auto/Off

Switch

Safety Valve

Safety Valve: If the pressure

 

 

switch does not shut off the

air compressor at its "cut-out" pressure setting, the safety valve will protect against high pressure by "popping out" at its factory set pressure (slightly higher than the pressure switch "cut-out" setting).

Outlet Pressure Gauge: The outlet pressure gauge indicates the air pressure available at the outlet side of the regulator. This pressure is controlled by the regulator and is always less than or equal to the tank pressure.

Tank Pressure Gauge: The tank pressure gauge indicates the reserve air pressure in the tank.

Regulator: Controls the air pressure shown on the outlet pressure gauge. Turn the knob clockwise to increase pressure and counterclockwise to decrease pressure.

Drain Valve: The drain valve is located at the base of the air tank and is used to drain condensation at the

end of each use.

Cooling System (not shown): This compressor contains an advanced design cooling system. At the

heart of this cooling system is an engineered fan. It is perfectly normal for this fan to blow air through the vent holes in large amounts. You know that the cooling system is working when air is being expelled.

Air Compressor Pump (not shown): Compresses air into the air tank. Working air is not available until the compressor has raised the air tank pressure above that required at the air outlet.

A08184

12- ENG

Image 12
Contents Oil-Free Air Compressor Safety Guidelines Definitions Important Safety InstructionsHazard Attachments & Accessories Electricity. Like any other electrically Hazard Warning Risk from Moving Parts Equip area of operation with a fire extinguisher Specifications AccessoriesGlossary Duty CycleTools Required for Assembly UnpackingAssemble Wheels Installation Location of the Air CompressorExtension Cords Voltage and Circuit ProtectionOperation Know Your Air CompressorDescription of Operation How to Stop Before StartingMaintenance How to StartBefore Each Start-Up Customer ResponsibilitiesTo Check Safety Valve Air Filter Inspection and ReplacementTo Drain Tank Service and Adjustments To Replace or Clean Check ValveAir Compressor Pump Intake and Exhaust Valves To Replace Regulator Storage Troubleshooting Problem Cause CorrectionBeing used Check wiring connection AIR Compressor Diagram Parts List Key Part Number DescriptionAIR Compressor Pump Diagram KEY Part Description Limited Warranty