DeWalt A08184 instruction manual How to Stop, Before Starting

Page 13

Check Valve: When the air compressor is operating, the check valve is "open", allowing compressed air to enter the air tank. When the air compressor reaches "cut-out" pressure, the check valve "closes", allowing air pressure to remain inside the air tank.

Check Valve

Pressure Release Valve: The pressure release valve located on the side of the pressure switch, is designed to automatically release compressed air from the compressor head and the outlet tube when the air compressor reaches "cut-out" pressure or is shut off. The pressure release valve allows the motor to restart freely. When the motor stops running, air will be heard escaping from this valve for a few seconds. No air should be heard leaking when the motor is running, or continuous leaking after unit reaches "cut-out" pressure.

How to Use Your Unit

How to Stop:

1.Set the On/Auto/Off lever to "OFF".

Pressure

Release

Valve

Before Starting

Break-in instructions

Serious damage may result if the following break-in instructions are not closely followed.

This procedure is required before the air compressor is put into service and when the check valve or a complete compressor pump has been replaced.

1.Make sure the On/Auto/Off lever is in the "OFF" position.

NOTE: If quick connect is installed, pull coupler back until it clicks to prevent air from escaping through the quick connect.

2.Plug the power cord into the correct branch circuit receptacle. (Refer to Voltage and Circuit Protection paragraph in the Installation section of this manual.)

3.Open the drain valve fully (counter-clockwise) to permit air to escape and prevent air pressure build up in the air tank during the break-in period.

NOTE: Always drain tank on a washable surface or in a suitable container to prevent damaging or staining surfaces.

4.Move the On/Auto/Off lever to "ON/AUTO" position. The compressor will start.

5.Run the compressor for 15 minutes. Make sure the drain valve is open and there is minimal air pressure build-up in tank.

6.After 15 minutes, close the drain valve (clockwise). The air receiver will fill to "cut-out" pressure and the motor will stop.

The compressor is now ready for use.

13- ENG

A08184

Image 13
Contents Oil-Free Air Compressor Important Safety Instructions Safety Guidelines DefinitionsHazard Attachments & Accessories Electricity. Like any other electrically Hazard Warning Risk from Moving Parts Equip area of operation with a fire extinguisher Accessories SpecificationsGlossary Duty CycleUnpacking Tools Required for AssemblyAssemble Wheels Location of the Air Compressor InstallationVoltage and Circuit Protection Extension CordsKnow Your Air Compressor OperationDescription of Operation Before Starting How to StopHow to Start MaintenanceBefore Each Start-Up Customer ResponsibilitiesAir Filter Inspection and Replacement To Check Safety ValveTo Drain Tank To Replace or Clean Check Valve Service and AdjustmentsAir Compressor Pump Intake and Exhaust Valves To Replace Regulator Storage Problem Cause Correction TroubleshootingBeing used Check wiring connection AIR Compressor Diagram Key Part Number Description Parts ListAIR Compressor Pump Diagram KEY Part Description Limited Warranty