DeWalt 5Z598C specifications Installation, Extension Cord, Grounding Instructions

Page 2

Speedaire Operating Instructions and Parts Manual

5Z598C

Speedaire® Portable Air Compressor

General Safety Information

E(Continued)

N

G4. Never use a motor with a higher

Lhorsepower rating than the one

Isupplied.

S5. Never drill into, weld or modify air

H tank.

Changing air tank will cause it to

weaken. Tank may rupture or explode.

6.Do not repair a leaking tank, it must be replaced. Never replace air tank with a different model or larger tank.

7.Never point any nozzle or sprayer toward a person or any part of the body.

8.Always wear safety goggles or glasses when using air compressor.

9.Check maximum pressure rating for air tools and accessories. Regulator outlet pressure must never exceed maximum pressure rating.

Damage may occur to air tools and

accessories if too much air pressure is applied.

Always unplug air compressor prior

to maintenance or repair. Never use air compressor outdoors when it is raining.

Never directly inhale the

compressed air produced by this unit. Compressed air contains toxic or irritating vapors which are harmful if inhaled.

10.Read labels and safety data for all materials you spray. Follow all safety precautions.

11.Use a mask or respirator if there is a chance of inhaling toxic sprayed materials. Masks and respirators have limits and will only provide protection against some kinds and limited amounts of toxic material. Read mask and respirator instructions carefully. Consult a safety expert or industrial hygienist if you are not sure about the use of a certain mask or respirator.

12.If the material you intend to spray contains trichloroethane and methylene chloride (read the label or the data sheet), do not use accessories that contain aluminum or galvanized parts. You must either change the material you intend to spray, or use only stainless steel spray equipment.

Trichloroethane and methylene

chloride can also react with galvanized components causing corrosion and weakening of equipment parts.

Installation

LOCATION OF AIR COMPRESSOR Locate air compressor in a clean, dry, well ventilated area. Air filter must be kept clear of obstructions, which could reduce air delivery of the air compres- sor. The air compressor should be located at least 12” away from the wall or other obstructions that will interfere with air flow. Air compressor head and shroud are designed to allow proper cooling. If humidity is high, air filter can be installed to remove excessive moisture. Follow air filter instructions for proper installation.

EXTENSION CORD

To avoid voltage drop and power loss to the motor use extra air hose instead of an extension cord. If an extension cord must be used, be sure it is:

1.A 3-wire extension cord that has a 3-blade grounding plug, and a 3- slot receptacle that will accept the plug on the product.

2.In good condition.

3.No longer than 50 feet.

4.12 gauge (AWG) or larger. Wire size increases as guage number decreases. 10 AWG and 8 AWG may also be used. (DO NOT USE A 14 OR 16 AWG.)

Compressor can be operated on a 15

amp circuit if:

1.Voltage supply to circuit is normal.

2.Circuit is not used to supply any other electrical needs (lights, appliances, etc.)

3.Extension cords comply with specifications in owners manual.

4.Circuit is equipped with 15 amp circuit breaker or 15 amp time delay fuse. Use a Type "T" time delay fuse.

If any of the above conditions cannot be met, or if operation of the compres- sor repeatedly causes interruption of the power, it may be necessary to operate it from a 20 amp circuit. It is not necessary to change the cord set.

GROUNDING INSTRUCTIONS

Improper

grounding can result in electrical shock. In the event of a short circuit, grounding reduces risk of shock by providing an escape wire for the electric current. Air compressor must be properly grounded.

2

Image 2
Contents Description SpecificationsGeneral Safety Information Breathable Air WarningGrounding Instructions InstallationExtension Cord Operation Maintenance Limited Warranty Troubleshooting Chart Symptom Possible Causes Corrective ActionCut-in pressure For Replacement Parts, Call Replacement Parts List for Compressor Pump Reference Description Part Number QtyFor Replacement Parts, Call Description Part Number KitsReference Description Number Part Number Qty 5Z598C