TECHNICAL SPECIFICATIONS
2 | 2.1 Electrical |
|
|
|
|
|
|
|
|
| |
|
| 12V / 24V, 4A Chargers | 12V, 8A Chargers |
| 24V, 8A Chargers | ||||||
| Nominal Operating Voltage | 120VAC |
|
| 230VAC | 120VAC | 230VAC |
| 120VAC | 230VAC | |
| Input Voltage (VAC) | 90 - 132 |
| 180 - 264 | 90 - 132 | 180 - 264 |
| 105 - 132 | 210 - 264 | ||
| Operating Frequency (Hz) |
|
|
|
| 47 - 63 |
|
|
| ||
| Input Current (A rms, max.) |
|
|
|
|
|
|
|
|
| |
| 12VDC nominal outputs | 1.0 @ |
| 0.5 @ | 2.0 @ | 1.0 @ |
| N/A | N/A | ||
| 90V/60Hz |
|
| 180V/50Hz | 90V/60Hz | 180V/50Hz |
| ||||
|
|
|
|
|
|
| |||||
| 24VDC nominal outputs | 2.0 @ |
| 1.0 @ | N/A | N/A |
| 4.0 @ | 2.0 @ | ||
| 90V/60Hz |
|
| 180V/50Hz |
| 105V/60Hz | 210V/50Hz | ||||
|
|
|
|
|
|
| |||||
| Input Leakage | <500 @ |
| <500 @ | <500 @ | <500 @ |
| <500 @ | <500 @ | ||
|
| (µA, max.) | 120V/60Hz |
|
| 230V/50Hz | 120V/60Hz | 230V/50Hz |
| 120V/60Hz | 230V/50Hz |
|
| Output Power (W, nom./max.) |
|
|
|
|
|
|
|
|
|
|
| 12VDC nominal outputs | 48 / 67.5 |
| 96 / 125 |
| |||||
|
| 24VDC nominal outputs | 96 / 135 |
| 192 / 240 |
| |||||
|
| Output Current (A, max.) |
| 4.0 |
|
| 8.0 |
| |||
|
| Output Voltage (VDC, nom./range) |
|
|
|
|
|
|
|
|
|
|
| 12VDC nominal outputs |
|
|
|
| 12 / 6.0 - 15.0 |
|
|
| |
|
| 24VDC nominal outputs |
|
|
|
| 24 / 12.0 - 30.0 |
|
|
|
2.2 Mechanical |
|
|
Case: |
| Aluminum alloy, black finish |
End caps: |
| Polycarbonate, black |
Dimensions (mm max.): |
| |
1604CS & 1604FV: | 160 L x 96 W x 52 H | |
1608FS: |
| 160 L x 140 W x 52 H |
Weight (kg) 1604/1608: | 1.0/1.5 | |
2.3 Connections |
|
|
AC Power Inlet: | IEC 320/C14 Male on cable | |
DC Power: | ITT Cannon | |
| Pin | Function |
1B+
2B-
3Motor Controller Charging Indicator
Programming Port: Molex
Held Programmer only. Pin Function
1Rx
2SEC_RTN
3Tx
4+12V
Output Adapters: |
|
| |
P/N | P/N | ||
Model 1288 Motor Controller | |||
Pin | Function | Pin | Function |
1 | Motor Controller | 1 | B+ |
| Charging Indicator | 2 | B- |
2 | B+ | 3 | B- (inhibit) |
3N/C
4N/C
5B-
6N/C
Charge Indicator: Low impedance capable of sinking 60 mA DC to
Remote LED: Some models come with a wire harness for remote LED capability. Contact your local Curtis sales office for details.
page 2 | Curtis 1604/08 Manual |