Curtis Computer 1604 Amp hour Capacity, End of Charge Mode, Fan Modulation Default setting Off

Page 8

Amp hour Capacity

Amp hour Capacity is the storage capacity of the battery, as defined by the battery's manufacturer. Selecting the appropriate amp hour capacity determines the longest period of time the charger will charge before automatically shutting off. If the charger is still charging at this point, it provides an error code to the operator. Refer to Section 5, Troubleshooting, to correct this error. Three Amp hour Capacity setpoints are available:

Option

Amp hour rating

Charge Cycle Timer (tc, see Fig. 1, 2, 3 and 4)

 

(4A / 8A charger)

(hours)

1

≤60 / ≤100

16

2

≤100 / ≤200

24

3

≤200 / ≤400

48

End of Charge Mode

End of Charge Mode defines how the charger terminates the charge cycle. There are three End of Charge Modes:

Option

Mode

Notes

1

End of Charge

Charge Profile: IVa

 

(see Figure 1)

Charger goes into standby upon reaching End of Charge

 

 

current. Charge will automatically restart if the standby

 

 

voltage falls below 12.9V (12V charger) 25.7V (24V charger),

 

 

and automatically self terminates. This compensates for battery

 

 

self-discharge over long periods of time. This mode is recommended

 

 

for daily use or for long term storage.

2

Equalize

Charge Profile: I1VI2a if previous mode was End of Charge

 

 

I1V1I2V2 if previous mode was Float.

 

(see Figure 2

After constant voltage terminates, charger adjusts its output

 

and Figure 4)

current to 1.5A/3A (4A/8A charger). The current is held

 

 

for either 3 hours or until the battery reaches 15.8V (12V

 

 

charger) or 30.5V (24V charger). The Equalize cycle automatically

 

 

reverts to the previous mode of charge termination after

 

 

the completion of 1 cycle. Check the battery manufacturer’s

 

 

recommendation regarding the frequency at which batteries

 

 

should be equalized.

3

Float

Charge Profile: IV1V2

 

(see Figure 3)

After constant voltage terminates, the charger reduces the

 

 

output current to 0.25A (24V charger), and cycles on and off

 

 

automatically to maintain an average battery voltage of (float

 

 

voltage, FV) 13.3V (12V charger) or 26.6VDC (24V charger).

 

 

This will continue until AC power is recycled. This mode of

 

 

charging is recommended for daily use or for short term

 

 

storage conditions to maintain battery health.

Fan Modulation - Default setting: Off

Fan Modulation can be turned on or off. If fan modulation is set to Off, the fan runs at full speed whenever the charger is charging. This maximizes charger power output over all operating conditions. If fan modulation is set to On, the speed of the fan is proportional to the temperature of the charger. This mode of operation is quieter.

page 6

Curtis 1604/08 Manual

Image 8
Contents Manual Important Safety Instructions WarrantyContents Technical Specifications ElectricalMechanical ConnectionsBattery Types EnvironmentalCompliance Charge Cycle ProfileInstallation Indication LightsCharging the Battery Setpoint VDC Battery ChemistryOperation Programming the ChargerEnd of Charge Mode Fan Modulation Default setting OffAmp hour Capacity ModeTop Off Settings Default setting Off To program the chargerEnd of Charge Profile with Equalize Problem Possible Causes & Solutions TroubleshootingMaintenance Curtis INSTRUMENTS, INC