3.Restart: If the battery
2.8Indication Lights
The charger features built in diagnostics. Refer to the table below to interpret the flashing of the yellow and green indicator lights. Flashing of the yellow indicator means that the charging cycle has ended early and the battery may not be fully charged. Refer to the Troubleshooting section to correct these faults.
Flash Pattern |
| Indication |
| ||
Yellow on |
| AC power present |
Green on |
| Charge complete |
Green blinking |
| Charging |
Yellow & Green on simultaneously |
| Charger in standby mode |
Yellow & Green blink simultaneously |
| No battery/reverse polarity |
Yellow blinks 1X |
| Not reaching constant voltage setpoint |
Yellow blinks 2X |
| Not reaching 24V within 2 hours |
Yellow blinks 3X |
| Charge current/voltage does not normalize |
Yellow blinks 4X |
| Battery voltage too high (over 32V) |
Yellow blinks 5X |
| Charger over temperature |
3 |
| INSTALLATION |
• | Charger should be securely mounted on a flat surface. | |
• | The power cord to the IEC 320/C14 connector should be of the appropriate | |
| gauge to carry a 10A current @ 120VAC, or a 5A current @ 230VAC for | |
| the cable’s length, to meet the requirements of applicable electrical codes. |
• A minimum of 30mm clearance should be provided at each end of the charger for vented models.
• The charger should not be installed in locations which restrict air flow.
page 4 | Curtis 1604/08 Manual |