PARTS OF THE RECEIVER

Figure 1. TW3008AR-4 Parts

￿Status LEDs (8): Light red when there is no UTP video being received. Light green when there is UTP video being received. Flashes amber when Coaxitron pan/tilt/zoom (PTZ) control commands are being transmitted.

￿Distance Dials (8): Override the adaptive technology with the manual selection of cable distance (1,000-4,000 feet or 305-1,219 meters). Auto high mode must be used when connecting to a balun or a Spectra® mini. Auto low mode must be used when connecting to Pelco UTP cameras, such as the CC3710/CC3610 Series.

￿Rack Ears (2): Removable for various mounting options.

￿UTP Connector (2.5 mm): 2-pin connector with removable mating connector.

￿BNC Connectors (32): Four coaxial outputs for each channel. Only BNC A of each channel can be used for Coaxitron control.

￿Barrel Connector (5 mm): Power from a 12 VDC universal power supply.

￿Molex Connector: 6-pin connector for use in a multi-unit installation with a rack-mountable external power supply.

6

C1668M (8/06)

Image 6
Contents TW3008AR-4 Active Receiver Page Important Safety Instructions Regulatory Notices Radio and Television InterferenceDescription ModelsParts of the Receiver Installation MountingSetting the Distance Dials Factory Default Dial PositionApplications Cable TypeShows a TW3008AR-4 connected to a UTP fixed camera TW3008AR-4 Connected to a Single Passive Transceiver TW3008AR-4 Connected to a 4-Channel Passive Transceiver Specifications ElectricalC1668M 8/06 Product Warranty and Return Information ISO9001