APPLICATIONS
You can connect the
Always connect the UTP wires on the Cat cable from + to + and from – to
Table A shows the maximum cable distance with Coaxitron or video only when connecting the
Table A. Cable Distance with TW3001P
Cable Type | Maximum Distance | Maximum Distance | |
(with Coaxitron) | (video only) | ||
| |||
|
|
| |
Cat3 | 750 ft (229 meters) | 1,500 ft (457 meters) | |
|
|
| |
Cat5 | 750 ft (229 meters) | 3,000 ft (914 meters) | |
|
|
| |
Cat5e | 750 ft (229 meters) | 4,000 ft (1,219 meters) | |
|
|
| |
Cat6 | 750 ft (229 meters) | 4,000 ft (1,219 meters) | |
|
|
|
Table B shows the minimum size for single wire and stranded wire.
Table B. Wire Gauge
Wire Gauge (minimum allowable)
Single Wire (solid) | 24 AWG (0.25 mm2) |
Stranded Wire (flexible) | 24 AWG (1.0 mm2) |
Figure 4 shows a TW3008AR-4 connected to a UTP Camclosure®.
MONITOR MONITOR MONITOR MONITOR
UTP | CAMCLOSURE |
| BLUE WIRE = |
| GRAY WIRE = |
12 VDC UNIVERSAL POWER SUPPLY
US
EU
UK
AU
Figure 4. TW3008AR-4 Connected to a UTP Camclosure