ALeft Leg
BRight Leg
CTable
DLeft Fence Bracket
ERight Fence Bracket/ Guard Assembly
FFence (2)
GRear Cutter Guard/ Dust Port
HHardware Package
JMiter Gage
A
Fig. 6
4.Mount the router base (see Fig. 6 for non-plunge routers, or Fig. 7 for plunge routers), to the underside of the table using screws from the hardware package (routers with less than 2 horsepower use three #10-24 x 3… 4" long screws, routers with more than 2 horsepower except Model 7529 use four
5… 16"-18 x 11… 4" screws, and Model 7529 uses three 10-24 x 11… 16" screws). Orient the router base directly below the large hole in the table, with the clamp screw (A) Fig. 6, (or the plunge locking lever (A) Fig. 7, on plunge models), toward the rear of the table.
NOTE: The router sub-base must be removed before mounting to table.
5.Place router motor into base and tighten clamp screw to secure (non- plunge models only).
6.Position the rear cutter guard (A) Fig. 8, to the right fence bracket and top cutter guard assembly. Secure with two #10-32 x 3… 8" screws.
NOTE: The rear cutter guard also provides a 21… 2" diameter dust collection port.
7.Position the right hand (in-feed) fence bracket and guard assembly (A) Fig. 9, to the slot on the right side of the table. Insert a 5… 16"-18 x 11… 4" carriage bolt (from the hardware package), up through the table and the fence bracket. Secure by threading on one of the black knobs.