Porter-Cable CFFN251T instruction manual Storage

Page 16

STORAGE

Before you store the air compressor, make sure you do the following:

1.Review the "Maintenance" section on the preceding pages and perform scheduled maintenance as necessary.

2.Set the On/Off switch to OFF (O) and unplug unit.

3.Turn the regulator counterclockwise and set the outlet pressure to zero.

4.Remove the air tool or accessory.

5.Pull ring on safety valve allowing air to bleed from the tank until tank pressure is approximately 20 psi. Release safety valve ring.

6.Drain water from air tank by opening drain valve on bottom of tank.

Risk of Bursting. Water will

condense in the air tank. If not drained, water will corrode and weaken the air tank causing a risk of air tank rupture.

7.After the water has been drained, close drain valve by turning clockwise.

NOTE: If drain valve is plugged, release all air pressure. The valve can then be removed, cleaned, then reinstalled.

8.Protect the electrical cord and air hose from damage (such as being stepped on or run over).

9.Store the air compressor in a clean and dry location.

A11894

16 - ENG

Image 16
Contents Instruction Pancake Manual Compressor Safety Guidelines Definitions Table of ContentsImportant Safety Instructions What Could Happen How To Prevent ItAlways remain in attendance with Attachments & Accessories Safety equipment must be properly Electricity. Like any other electricallyRepairs attempted by unqualified Personnel can result in serious injuryResult in serious burns How To Prevent It Hazard Warning Risk from Moving PartsKeep children away from the air compressor at all times Never defeat the safety features of thisEquip area of operation with a fire extinguisher Specifications AccessoriesGlossary Duty CycleAssembly InstallationUnpacking Location of the Air CompressorExtension Cords Voltage and Circuit ProtectionOnI/OffO Switch Tank Pressure Gauge Outlet Safety Valve RegulatorOperation Know Your Air CompressorBefore Starting Before Each Start-UpDrain Check ValveMaintenance How to StartTo Check Safety Valve Customer ResponsibilitiesService and Adjustments To Replace or Clean Check ValveTo Drain Tank Hose Clamp Check ValveSafety Valve Gauges Quick Connect To Replace RegulatorPump Mounting Screw Regulator ManifoldStorage Troubleshooting Problem Cause CorrectionBeing used Service Warranty Warranty Registration Limited Warranty