Porter-Cable CFFN251T instruction manual Specifications, Glossary, Duty Cycle, Accessories

Page 8

SPECIFICATIONS

Model Nos.

CFFN251T

Bore

1.875"

Stroke

1.250"

Voltage-Single Phase

120

Minimum Branch Circuit Requirement

15 amps

Fuse Type

Time Delay

Air Tank Capacity (Gallon)

6

Approximate Cut-in Pressure

110 PSIG

Approximate Cut-out Pressure

135 PSIG

SCFM @ 40 PSIG

3.7

SCFM @ 90 PSIG

2.6

GLOSSARY

Become familiar with these terms before operating the unit.

CFM: Cubic feet per minute.

SCFM: Standard cubic feet per minute; a unit of measure of air delivery.

PSIG: Pounds per square inch gauge; a unit of measure of pressure.

Code Certification: Products that bear one or more of the following marks: UL, CUL, ETL, CETL, have been evaluated by OSHA certified independent safety laboratories and meet the applicable Underwriters Laboratories Standards for Safety.

Cut-In Pressure: While the motor is off, air tank pressure drops as you continue to use your accessory.

When the tank pressure drops to a certain low level the motor will restart automatically. The low pressure at which the motor automatically restarts is called "cut-in" pressure.

Cut-Out Pressure: When an air compressor is turned on and begins to run, air pressure in the air tank begins to build. It builds to a certain high pressure before the motor automatically shuts off - protecting your air tank from pressure higher than its capacity. The high pressure at which the motor shuts off is called "cut-out" pressure.

Branch Circuit: Circuit carrying electricity from electrical panel to outlet.

DUTY CYCLE

This air compressor pump is capable of running continuously. However, to prolong the life of your air compressor, it is recommended that a 50%-75%

average duty cycle be maintained; that is, the air compressor pump should not run more than 30-45 minutes in any given hour.

ACCESSORIES

Accessories for this unit are available at the store the unit was purchased.

A11894

8 - ENG

Image 8
Contents Instruction Pancake Manual Compressor Important Safety Instructions Table of ContentsSafety Guidelines Definitions Always remain in attendance with How To Prevent ItWhat Could Happen Attachments & Accessories Safety equipment must be properly Electricity. Like any other electricallyRepairs attempted by unqualified Personnel can result in serious injuryResult in serious burns How To Prevent It Hazard Warning Risk from Moving PartsEquip area of operation with a fire extinguisher Never defeat the safety features of thisKeep children away from the air compressor at all times Specifications AccessoriesGlossary Duty CycleAssembly InstallationUnpacking Location of the Air CompressorExtension Cords Voltage and Circuit ProtectionOnI/OffO Switch Tank Pressure Gauge Outlet Safety Valve RegulatorOperation Know Your Air CompressorBefore Starting Before Each Start-UpDrain Check ValveMaintenance How to StartTo Check Safety Valve Customer ResponsibilitiesService and Adjustments To Replace or Clean Check ValveTo Drain Tank Hose Clamp Check ValveSafety Valve Gauges Quick Connect To Replace RegulatorPump Mounting Screw Regulator ManifoldStorage Troubleshooting Problem Cause CorrectionBeing used Service Warranty Warranty Registration Limited Warranty