Porter-Cable C3150 instruction manual Before Each Start-Up

Page 13

Before Starting Break-in instructions

Serious damage may result if the following break-in

instructions are not closely followed.

This procedure is required before the air compressor is put into service and when the check valve or a complete compressor pump has been replaced.

1.Make sure the On/Auto/Off lever is in the "OFF" position.

NOTE: If quick connect is installed, pull coupler back until it clicks to prevent air from escaping through the quick connect.

2.Plug the power cord into the correct branch circuit receptacle. (Refer to Voltage and Circuit Protection paragraph in the Installation section of this manual.)

3.Open the drain valve fully (counter-clockwise) to permit air to escape and prevent air pressure build up in the air tank during the break-in period.

4.Move the On/Auto/Off lever to "ON/AUTO" position. The compressor will start.

5.Run the compressor for 15 minutes. Make sure the drain valve is open and there is minimal air pressure build-up in tank.

6.After 15 minutes, close the drain valve (clockwise). The air receiver will fill to “cut-out” pressure and the motor will stop.

The compressor is now ready for use.

Before Each Start-Up:

1.Place On/Auto/Off lever to “OFF”.

2.Pull regulator knob out, turn counter-clockwise until it stops. Push knob in to lock in place.

3.Attach hose and accessories. NOTE: The hose or accessory will require a quick connect plug. To use remote console, see "How to Use Remote Console" paragraph in this section.

Too much air pressure causes a hazardous risk of bursting. Check the manufacturer’s maximum pressure

rating for air tools and accessories. The regulator outlet pressure must never exceed the maximum pressure rating.

13- ENG

D28299

Image 13
Contents C3150 ModelImportant Safety Instructions Safety Guidelines DefinitionsHazard Attachments & Accessories Electricity. Like any other electrically Result in serious burns Fire, Inhalation, Damage to Vehicle Surfaces Glossary SpecificationsDuty Cycle Assembly AccessoriesInstallation UnpackingVoltage and Circuit Protection Extension CordsKnow Your Air Compressor Description of Operation OperationHow to Stop How to Use Your UnitBefore Each Start-Up How to Use Remote Console How to StartTo Check Safety Valve MaintenanceCustomer Responsibilities To Drain Tank Air Filter Inspection and ReplacementAir Compressor Pump Intake and Exhaust Valves To Replace or Clean Check Valve Service and AdjustmentsStorage Problem Cause Correction TroubleshootingPressure reading Check wiring connection Limited Warranty