Porter-Cable C3150 instruction manual Glossary, Duty Cycle, Specifications

Page 8

GLOSSARY

Become familiar with these terms before operating the unit. CFM: Cubic feet per minute.

SCFM: Standard cubic feet per minute; a unit of measure of air delivery.

PSIG: Pounds per square inch gauge; a unit of measure of pressure.

Code Certification: Products that bear one or more of the following marks: UL, CUL, ETL, CETL, have been evaluated by OSHA certified independent safety laboratories and meet the applicable Underwriters Laboratories Standards for Safety.

Cut-In Pressure: While the motor is off, air tank pressure drops as you continue to use your accessory. When the tank pressure drops to a certain low level the motor will restart automatically. The low pressure at which the motor automatically restarts is called “cut-in” pressure.

Cut-Out Pressure: When an air compressor is turned on and begins to run, air pressure in the air tank begins to build. It builds to a certain high pressure before the motor automatically shuts off - protecting your air tank from pressure higher than its capacity. The high pressure at which the motor shuts off is called “cut-out” pressure.

Branch Circuit: Circuit carrying electricity from electrical panel to outlet.

DUTY CYCLE

This air compressor pump is capable of running continuously. However, to prolong the life of your air compressor, it is recommended that a 50%-75% average duty cycle be maintained; that is, the air compressor pump should not run more than 30-45 minutes in any given hour.

 

 

 

 

 

SPECIFICATIONS

 

 

 

Model No.

C3150

 

 

Horsepower Peak

3.5

 

 

Bore

2.375"

 

 

Stroke

1.350"

*

 

Voltage-Single Phase

120

* *

Minimum Branch Circuit Requirement

15 amps

*

 

Fuse Type

Time Delay

 

 

Air Tank Capacity (Gallon)

4.5

 

 

Approximate Cut-in Pressure

120 PSIG

 

 

Approximate Cut-out Pressure

150 PSIG

 

 

SCFM @ 90 PSIG

6.0

*

 

 

 

 

This air compressor can be operated on a 15 amp

 

 

 

 

 

 

 

 

 

 

 

 

 

circuit if:

 

 

 

 

 

 

 

1.Voltage supply to circuit is normal.

2.Circuit is not used to supply any other electrical needs (lights, appliances, etc.)

3.Extension cords comply with specifications in owners manual.

4.Circuit is equipped with 15 amp circuit breaker or 15 amp time delay fuse.

If any of the above conditions cannot be met, or if operation of the air compressor repeatedly causes interruption of the power it may be necessary to operate it from a 20 amp circuit. It is not necessary to change the cord set.

** A circuit breaker is preferred. Use only a fuse or circuit breaker that is the same rating as the branch circuit on which the air compressor is operated. If the air compressor is connected to a circuit protected by fuses, use dual element time delay fuses.

D28299

8- ENG

Image 8
Contents Model C3150Safety Guidelines Definitions Important Safety InstructionsHazard Attachments & Accessories Electricity. Like any other electrically Result in serious burns Fire, Inhalation, Damage to Vehicle Surfaces Duty Cycle SpecificationsGlossary Accessories AssemblyInstallation UnpackingExtension Cords Voltage and Circuit ProtectionOperation Know Your Air Compressor Description of OperationHow to Use Your Unit How to StopBefore Each Start-Up How to Start How to Use Remote ConsoleCustomer Responsibilities MaintenanceTo Check Safety Valve Air Compressor Pump Intake and Exhaust Valves Air Filter Inspection and ReplacementTo Drain Tank Service and Adjustments To Replace or Clean Check ValveStorage Troubleshooting Problem Cause CorrectionPressure reading Check wiring connection Limited Warranty