If the readings are different, the table needs adjusting.
2.Disconnect sander from power source.
3.At the area of the table that needs adjustment, loosen the two screws (A, Figure 18) on the bracket of the elevation screw, and rotate the bracket as needed. (The elevation screw is protected by the dust guard bellow.) Turn the elevating screw clockwise to lower the table in that area, counterclockwise to raise the table (see Figure 18).
IMPORTANT: Turn both elevating screws at one side of the table an equal amount, in order to maintain
4.Tighten screws (A, Figure 18).
5.
10.0Operating Controls
Figure 19 shows the control panel functions.
The emergency stop button shuts down all machine operations. The button remains engaged after being pushed. To disengage, rotate the ring until the emergency stop button pops back out.
The emergency stop cover has a plate (shown in Figure 16) which shuts down all machine operations when it is pushed.
10.1Amperage Meter
The amperage meter (Figure 19) continually monitors the load upon the sander. To avoid tripping of the circuit breaker and the overload relays, reduce the load immediately when the amperage meter indicates excessive amperage pull.
10.2LED Controller and Keypad
The controller is used for precise positioning of the conveyor table based upon the workpiece thickness and your desired sanding depth.
Figure 20 shows the key features of the unit.
The LED control unit comes
Figure 18
Figure 19
Figure 20
18