MITRE GAUGE & CLAMP
Mount mitre gauge and clamp to the sliding table as follows (Figure 19):
1.Insert post (A) of the clamp assembly down through hole (B) of the mitre gauge body (C), and thread post (A) into hole (D) of sliding table.
2.Insert shaft of locking handle (E) down through opening (F) of mitre gauge and thread shaft into hole
(G) of sliding table.
3.The clamp (H), shown in Figure 20, is supplied with the mitre gauge to securely hold the workpiece when shaping small pieces across the grain. The clamp should be mounted as shown, and can be ad- justed by loosening the screws (J).
MITRE FENCE
1.Slide the mitre fence (A) on to the two square nuts (B) that are attached to the threaded part of the locking levers (C). See Figure 21.
2.To slide mitre fence (A) to the left or right, loosen locking levers (C), slide fence (A) to the desired posi- tion and tighten locking levers (C). To change the angle of the fence loosen locking handle (D). A scale (E) is provided to indicate the mitre angle of the fence.
3.Loosen locking screw (I) and insert nut (J) of stock stop assembly into channel on end of fence as shown. See Figure 22.
4.Slide workstop (K) to desired position on fence and tighten locking screw (I), as shown in Figure 23.
FIGURE 22
FIGURE 19
FIGURE 20
FIGURE 21
FIGURE 23
13