Multiquip operation manual FS 1 Concrete SAW- Initial START-UP

Page 25

FS 1 CONCRETE SAW— INITIAL START-UP

CAUTION:

DO NOT attempt to operate the saw until the Safety, General Information and Inspection sections have been read and understood. Depending on engine manufacturer, operating steps may vary. See engine manufactures

operating manual. The following start-up procedure makes reference to a HONDA engine.

1.Ensure the diamond blade has been mounted correctly and that it raised above the surface you about to saw.

2.Connect to water source (as applicable) see item 7 on page

48 (Water System Assembly), and test for adequate flood water [ 4 to 5 gallons per minute (15 to 19 LT/min)], and/or misting water [steady geometric aerosol spray at 40 psi].

3.Place the fuel valve lever (Figure 17) to the "ON" position.

Figure 17. Fuel Valve Lever

4.Place the Engine ON/OFF switch (Figure 18) in the "ON" position.

The CLOSED position of the

choke lever enriches the fuel

NOTEmixture for starting a COLD engine. The OPEN position provides the correct fuel mixture for normal operation after starting, and for restarting a warm engine.

5. Place the Choke Lever (Figure 19) in the "OPEN" position

Figure 19. Choke Lever

CAUTION:

The engine governor speed has been set at the factory. Changing the governor speed could damage the blade and/or the saw.

6.Place the throttle lever (Figure 20) halfway between fast and slow for starting. All sawing is done at full throttle. The

engine governor speed is factory set to ensure optimum blade operating speeds.

Figure 18. Engine ON/Off Switch

Figure 20.Throttle Lever

MQ-WHITEMAN FS1 CONCRETE SAW — PARTS & OPERATION MANUAL — REV. #3 (04/24/03) — PAGE 25

Image 25
Contents Concrete SAW Page Heres HOW to GET Help Table of Contents Parts Ordering Procedures Seriously injured if you do not follow directions FS 1 Concrete SAW Safety Message Alert SymbolsAlways wear approved respiratory protection FS 1 Concrete SAW Safety Message Alert SymbolsAlways wear approved eye and hearing protection FS 1 Concrete SAW Decals Machine Safety DecalsFS 1 Concrete SAW Rules for Safe Operation General SafetyFS 1 Concrete SAW Rules for Safe Operation Stop the engine when leaving the saw unattendedNever tow the saw behind a vehicle Never transport the saw with the blade mountedFS 1 Concrete SAW Rules for Safe Operation Maintenance SafetyEmergencies FS 1 Concrete Saw Dimensions FS 1 Concrete SAW DimensionsCrated Weight kgs lbs Weight kgsFS 1 Concrete Saw Basic Components FS 1 Concrete SAW Basic ComponentsDescription FS 1 Concrete SAW Basic Engine Components Manual FS 1 Concrete SAW General InformationFS 1 Concrete SAW General Information Water Connection/Manual/Raise Lower AssemblyFS 1 Concrete SAW Inspection -ENGINE Read safety instructions at the beginning of manualBefore Starting Engine Oil CheckOperating area Rotation downcuts with the turn of the shaftPoor performance and/or blade damage Blade and the saw61-68 N/m when finalizing the assembly FS 1 Concrete SAW Inspection -BLADE PlacementPosition Tight closure on the surface of the bladeDiamond Blade Placement Procedure FS 1 Concrete SAW Inspection -BLADE PlacementGuards and Covers Check FS 1 Concrete SAW Inspection -GUARDS, Covers ANDV-BELTSB7.5 Check the following on the blade flange coverBelt Tension FS 1 Concrete SAW- Initial START-UP Place the Engine ON/OFF switch in the on positionManeuvering The Saw Stopping the EngineBlade is spinning whenever the engine is running Saw Alignment FS 1 Concrete SAW OperationWet Saw Operation Advance engine throttle to full Fast positionFinishing a Cut Dry Saw OperationDiamond Blades and Blade Speed Blade SpeedGeneral Cleanliness FS 1 Concrete SAW MaintenanceBearing Lubrication Care General Engine CareRight-Side Shaft Bearing Blade Shaft Bearing ReplacementRe-install the V-belt guard Belt ReplacementBelt Tension Check FS1 14 Model ShownEngine Troubleshooting FS 1 Concrete SAW Troubleshooting EngineEngine Troubleshooting FS 1 Concrete SAW Troubleshooting EngineBlade Troubleshooting FS 1 Concrete SAW Troubleshooting BladeFS 1 Concrete SAW Note Items Found In the Items Number Column Items Found In the Remarks ColumnTo 3 Units FS 1 Concrete SAW Suggested Spare PartsFS 1 Concrete SAW Under Carriage Assy 0730 SCREW, HHC 1/4-20 X 0948 10024 NUT, Nyloc 1/4-20 503078503602 10024 NUT, Nyloc 1/2-13 511471FS 1 Concrete SAW Blade Shaft Assy FS 1 Concrete SAW Blade Shaft Assy FS 1 Concrete SAW Frame Assy 511436 511432511502 503015FS 1 Concrete SAW Cover Assy 592623 5030120655 SCREW, HHC 5/16 18 X 3/4 492597 503014FS 1 Concrete SAW Blade Guard Assy 503082 26250 SCREW, HHC 1/4 20 X 13/4 503103503083 503079FS 1 Concrete SAW Water System Assy 491237 503124503108 HOSE, 1/2 FS 1 Concrete SAW Manual Raise and Lower Assy 503093 4910196 KNOB, 3/8 NC 503013503094 FS 1 Concrete SAW Engine Assy 12.0 H.P. Kohler Model PA-941502 H.P. Kolher Model PA-951502492054 512891Terms and Conditions of Sale Parts Page Warranty Department Main

FS 1 specifications

The Multiquip FS 1 is a versatile piece of equipment designed for efficient fuel management and transfer. Catering primarily to construction sites, agriculture, and industrial applications, the FS 1 is known for its compact design, robust performance, and reliable functionality.

One of the main features of the Multiquip FS 1 is its high-capacity fuel tank, which is engineered to hold a substantial volume of diesel or gasoline, allowing users to refuel equipment without frequent interruptions. This fuel tank is equipped with a durable, weather-resistant cover that ensures protection against various environmental factors, extending the life of the equipment.

In terms of technology, the FS 1 incorporates advanced pumping systems that facilitate rapid fuel transfer. The pump is designed for low noise operation, reducing disturbances on job sites while ensuring efficient fuel flow. Furthermore, the inclusion of an automatic shutoff feature ensures safety during fueling operations by preventing overflows and spills, thus minimizing environmental risks.

The FS 1 is characterized by its mobility. Equipped with sturdy wheels and a reliable tow hitch, it can be easily transported from one location to another, simplifying the logistics of fuel distribution on-site. This portability is particularly beneficial in large construction projects where multiple machines require fueling at varied intervals.

Ergonomically designed, the FS 1 features user-friendly controls that simplify operation. Operators can easily manage fuel transfers, check gauge readings, and monitor flow rates without extensive training. Additionally, the FS 1 is designed to be compatible with various fuel nozzles, making it a versatile choice for different fueling needs.

The construction of the FS 1 emphasizes durability and longevity. Built with high-quality materials, it is resistant to corrosion and wear, making it suitable for demanding environments. The design also prioritizes ease of maintenance, with accessible components that allow for quick inspections and repairs.

In summary, the Multiquip FS 1 stands out for its combination of efficiency, safety, and mobility. It is an essential tool for professionals who require a reliable fuel management solution that is easy to operate and maintain. With its innovative design and advanced features, the FS 1 simplifies the fueling process, allowing users to focus on their core tasks and enhancing overall productivity on the job site.