Omega Vehicle Security CCT-80 Series manual Open the Housing, Internal Overview, Procedure

Page 4

OPEN THE HOUSING

A

C

 

 

d

PROCEDURE

 

 

c

 

 

1. Insert a screwdriver or similar tool in the

c

e

 

points marked c.

d

 

 

2. Turn the screwdriver until the case walls

 

B

begin to separate towards A and B, so the

 

e

two side lugs e, are free.

 

 

3.Grab the Signal Conditioner body, at the points marked d‚ and pull it towards C, until the two side lugs e are out of their

housing and the internal circuits are visible. See the sketch below for the disassembly of the circuit boards.

4. Before reinserting the Signal Conditioner

FIG.1

body into the case, the following must be

 

checked :

 

-The front label (blue color) must be in its correct position, with terminals 1 and 7 (power supply) separated from the other terminals.

-The three internal modules must be inserted correctly in their internal case guides.

MA

Power Supply Module

INTERNAL OVERVIEW

A. "ME" Input module.

B. "MS" Output module.FIG.2 C. "MA" Power supply module.

D. "MP" Input Board.

PROCEDURE FOR DISASSEMBLY

1.Pull out the "ME" input module towards "a".

2.Pull out the "MS" output module towards "a".

3.Pull out the "MP" input board towards "b".

4.To assemble reverse the procedure.

a

A

C

MP

Input board

D

b

a

B

3

ME Input module

MS Output module

 

 

 

Image 4
Contents User’sGuide Omega.comTM Table of Contents Open the Housing ProcedureProcedure for Disassembly Internal OverviewRecommended Wiring PrecautionsChanging the Power Supply ProtectionsChanging the Signal Output NON Standard Output Voltages CurrentsOffset Adjust OverviewCCT-80, Electrical Features General SpecificationsInput OutputAdjustment and Calibration Procedure Signal Input Range SelectionTare Adjust Procedure Wire Wiring ConnectionsTare Adjust BridgeTechnical Data DimensionsMechanical Page USAWARRANTY/DISCLAIMER Temperature