Omega Vehicle Security CCT-80 Series manual CCT-80, Electrical Features, Input, Output

Page 8

CCT-80, ELECTRICAL FEATURES

This signal conditioner provides connection to 4- or 6-wire strain-gages (load-cells), which provide a nominal of 2 mV/V or 3 mV/V output with 350 impedance. See the Connections Section.

The signal conditioner does not provides the bridge excitation voltage, therefore is necessary to use an external auxiliary power supply. It is advised that you use the model FAR-1 power supply, which senses the excitation voltage and compensates the errors due to lead resistance.

The FAR-1 provides a regulated 10 Vdc output.

The CCT-80 has an internal circuit which provides the user with tare adjust and compensation. See the tare paragraph.

INPUT

STANDARD SIGNAL

20 mV

TARE

by internal trimmer PT1, located on the "MP"

 

input board

OUTPUT

0 to 20 mA or 4 to 20 mA

RL< 600 max. 22 mA ±3%

0 to 10 Vdc

RL> 1000 max. 11 V ±3%

ACCURACY

0.2 % FS

RESPONSE TIME

250 mS

GALVANIC ISOLATION

Input, Output and Power Supply are all isolated

 

to 2 kVeff. 50 Hz/1 m.

GENERAL SPECIFICATIONS

 

 

RIPPLE

0.5 %

BAND PASS

1.5 Hz (-3 dB)

STORAGE TEMPERATURE

-30° to +80°C

OPERATING TEMPERATURE

-10° to +60°C

TEMPERATURE COEFFICIENT

0.015 %/°C

STANDARD POWER SUPPLY

115 Vac (±10%) 50/60 Hz

POWER CONSUMPTION

1.5 VA

TEST VOLTAGE

4 kVeff. 50 Hz/1m.

7

Image 8
Contents User’sGuide Omega.comTM Table of Contents Open the Housing ProcedureProcedure for Disassembly Internal OverviewRecommended Wiring PrecautionsChanging the Power Supply ProtectionsChanging the Signal Output NON Standard Output Voltages CurrentsOffset Adjust OverviewCCT-80, Electrical Features General SpecificationsInput OutputTare Adjust Procedure Signal Input Range SelectionAdjustment and Calibration Procedure Wire Wiring ConnectionsTare Adjust BridgeMechanical DimensionsTechnical Data Page USAWARRANTY/DISCLAIMER Temperature