4. SUPPLY VOLTAGE

The DRA-DCC-8 is powered by a DC power supply at a range of 15-32Vdc. In order to determine the minimum supply voltage, use the following equation:

Vmin = 8 + Rload() * 0.02

where:

Vmin is the minimum required supply voltage.

Rload() is the maximum output load including the leads resistance.

Note: If Vmin turns to be less than 15V, the minimum required voltage should be 15 Vdc.

5. MODES OF OPERATION

The DRA-DCC-8 unit can be operated in several modes, determined by an internal array of 8 DIP switches as follows:

4-20 or 0-20mA output current mode

Parallel control mode

Serial control mode

Self test mode

5.1 0-20 OR 4-20mA OUTPUT CURRENT MODE

Two current output spans are available: 4-20mA or 0-20mA selected by SW6. The DRA-DCC-8 receives 12 bits of data which determine the output current value. A channel data value of 4095 (FFF) is always interpreted as a 20mA output current. A channel data value of 0 (000) will produce a 0mA output current when SW6 is OFF, or 4mA when ON.

5.2 SWITCH SETTINGS

Parallel Control Mode

MODE

S1

S2

S3

S4

S5

S6

S7

0-20mA

OFF

OFF

X

X

X

OFF

OFF

4-20mA

OFF

OFF

X

X

X

ON

OFF

3

Image 5
Contents User’s Guide Omega.comTM Contents Replacing Fuses AssemblyMounting Instructions Switch Settings 0-20 or 4-20mA Output Current ModeParallel Control Mode Supply VoltagePLC Interface Parallel Control ModeSerial Control Mode E Enable Terminal Serial Control ModeSerial Control Switch Settings RS422 TerminationThree types of command formats are available Command FormatsBaud Rate Select Without Echo Back FormatStatus Report Format Self Test ModesPutting the Unit Into Operation Multidrop ConfigurationSelf Test #1 Communication Ports Test Self Test #2 Same LevelDRA-DCC-8 Calibration Relative Humidity Housing WARRANTY/DISCLAIMER Temperature