W & W Manufacturing X3 & X6 manual Impedance Test, Selecting Impedance Results

Page 6

Parts Overview

Adapter cups

Printer Port

1

EMPTY

2 EMPTY

3 EMPTY

Impedance Test

Impedance of a battery can be a good indicator of degradation of a battery’s performance. In general, the lower the impedance number the better the battery performance during discharge. As a battery ages the impedance starts to rise indicating possible problems with the electrolyte, separator, contact corrosion, or

metal interfaces, all impact the impedance.

The initial impedance of a new battery should be recorded and compared through the life of a battery and a determination can be made to remove the battery from service when the impedance rises out of range.

The Analyzer X3 and X6 produce impedance results within a 15 seconds of testing and displays the impedance in Ohms on the display or on a printout when an optional printer is used.

Follow the directions below for Impedance testing.

This test is only performed in Pocket #1 for the X3 and pockets #1 and #4 for the X6.

SELECTING “IMPEDANCE “

AND RESULTS

ACTION

Analyzer X3

DISPLAY

 

FUNCTION BUTTONS

 

 

 

 

 

 

On/Off Switch

 

 

 

 

 

Power in Receptacle

Serial Port

 

 

 

 

 

Serial Port

(Computer) DB9-female

 

(Printer) DB9-Male

Rear view of Analyzer X3

Hi Power in Receptacle

optional

On/Off Switch

Power in Receptacle

Display After “Turn On”

After the battery is placed in the adapter

PUSH FUNCTION until battery specs appear in the display

NO ACTION

PUSH

PUSH

PUSH

PUSH

NO ACTION

NO ACTION

EMPTY

TO PROCEED PRESS

<FUNCTION>

NICD 700 MAH 7.2V

<FUNCTION> FOR NEXT

NICD 700 MAH 7.2V HAS BEEN SELECTED

QUICK TEST

<FUNCTION> FOR NEXT

CYCLE/AUTO/CONDITION <FUNCTION> FOR NEXT

DIS -CHRG BATTERY

<FUNCTION> FOR NEXT

CHARGE BATTERY

<FUNCTION> FOR NEXT

IMPEDANCE TEST

<FUNCTION> FOR NEXT

IMPEDANCE TEST

HAS BEEN SELECTED

Serial Port

Serial Port

(Computer) DB9-female

(Printer) DB9-Male

 

Rear view of Analyzer X6

6

NO ACTION

TESTING

 

FOR RESULTS PUSH

READY

PUSH

BATTERY IMPEDANCE

.233 ohms

 

15

Image 6
Contents Analyzer X3 Table of Contents Safety and Operating Environment Features Universal cupX3 & X6 Specifications Selecting LearnResults Impedance Test Selecting Impedance ResultsCharge Mode Selecting Charge ResultsSelecting Discharge Results Getting StartedSelecting Condition Results Condition ModeSelecting Quick Test Results Quick Test AnalysisCycle Mode Selecting Cycle ResultsSelecting Auto Results