W & W Manufacturing X3 & X6 Selecting Quick Test Results, Condition Mode, Quick Test Analysis

Page 9

Condition Mode

The CONDITION CYCLE serves basically two needs of Nickel based batteries, one is to reform the Cells of a battery that hasn’t been used for an extended period of time, say for 3 or more Months. Secondly this mode will eliminate MEMORY EFFECT better known as VOLTAGE DEPRESSION.

Usually deep discharging the battery will restore the battery back to normal capacity such as the discharging and charging cycle used in the Analyzer X3 and X6.

Lithium Ion batteries do not suffer from voltage depression, but they will not be harmed if the Conditioning cycle is applied to them. To select the condition cycle follow the instructions below.

With the X3 and X6, the percentage of the rated capacity of the battery being CONDITIONED is set at 80%, the 80% is set at the factory and can be modified with the use of optional software.

SELECTING “ CONDITION “

AND RESULTS

ACTION

QUICK TEST ANALYSIS

This is an advanced proprietary algorithm capable of determining the health of a battery. Specially stored parameters allowing the Analyzer X3 or X6 to identify a battery’s range of capacity and display: Batt>60% or Batt<60%of rated capacity . Batteries that have a low state of charge when placed in the X3 for the QT May require a charge of up to 10 minutes before performing the QT. Up to 3 attempts to charge the battery will be tried before a message is displayed “Discard the Battery”.

Even batteries that do not have pre-stored parameters can have a QT on, but will first be required to go through the “ Learn Mode”. Note, first a good battery must be learned before QT can be performed .

A impedance test must be performed prior to the “Learn Mode”, and incorporated into the LEARN MODE.

SELECTING “ QUICK TEST “

 

RESULTS

 

 

 

 

ACTION

DISPLAY

 

Display After “Turn On”

After the battery is placed in the adapter

EMPTY

TO PROCEED PRESS

<FUNCTION>

Display After “Turn On”

EMPTY

 

 

 

 

PUSH FUNCTION BUTTON until battery

specs appear in the display

NO ACTION

PUSH

NO ACTION

NO ACTION

PUSH

NO ACTION

NO ACTION

NICD 700 MAH 7.2V

<FUNCTION> FOR NEXT

NICD 700 MAH 7.2V HAS BEEN SELECTED

QUICK TEST

<FUNCTION> FOR NEXT

CYCLE/AUTO/CONDITION <FUNCTION> FOR NEXT

CYCLE/AUTO/CONDITION

HAS BEEN SELECTED

CYCLE 1

<FUNCTION> FOR NEXT

CONDITION TO 80%

<FUNCTION> FOR NEXT

CONDITION TO 80% HAS BEEN SELECTED

After the battery is placed in the adapter

PUSH FUNCTION BUTTON until battery

specs appear in the display

NO ACTION

NO ACTION

NO ACTION

TO PROCEED PRESS

<FUNCTION>

LION 1650 MAH 7.4V

<FUNCTION> FOR NEXT

LION 1650 MAH 7.4V HAS BEEN SELECTED

QUICK TEST

<FUNCTION> FOR NEXT

QUICK TEST

HAS BEEN SELECTED

 

NO ACTION

TESTING

 

NO ACTION

READY

 

 

PUSH

FOR RESULTS

CONDITION - DONE 1

CAP= 85% 595 MAH

 

 

NO ACTION

PUSH FOR RESULTS

TEST

READY

12

REMOVE BATTERY

QUICK TEST ANALYSIS

 

BATT>60% 0R BATT<60%

 

 

 

9

Image 9
Contents Analyzer X3 Table of Contents Safety and Operating Environment Universal cup FeaturesX3 & X6 Specifications Selecting LearnResults Selecting Impedance Results Impedance TestSelecting Charge Results Charge ModeGetting Started Selecting Discharge ResultsSelecting Quick Test Results Condition ModeSelecting Condition Results Quick Test AnalysisCycle Mode Selecting Cycle ResultsSelecting Auto Results