Kompernass TLG 1000 A1 Commissioning, Charging batteries, Block batteries in the charging slots 5

Page 6

Commissioning

Before taking the Battery Charger into use, check that all items are complete/available and free of visible damage.

Place the Battery Charger on a straight, level, scratch and slip resistant surface.

Notice:

This appliance is equipped with non slip rubber feet. As furniture surfaces may be made of a variety of materials and are treated with many different types of cleaning agents, it cannot be completely ruled out that some substances contain ingredients which may corrode the rubber feet and soften them. If pos sible, place an anti slip material under the device.

Compare the technical data with that of your current mains power supplier. If they are the same, connect the power cable to a mains power socket. The LEDs blink red three times. The Battery Charger is now ready for use.

Charging batteries

Danger!

Charge exclusively rechargable batteries of the types „Ni Cd“ and „Ni MH“.

NEVER recharge batteries of other types or non rechargable batteries. These are not suitable for recharging. They could irreparably damage the Battery Charger and the inserted batteries. There is also the danger of a fire as well as an explosion!

Notice:

Ensure that the batteries are inserted into the charging slots in accordance with their polarities. Otherwise, the batteries will not be charged.

Insert the batteries into the charging slots.

Press the 9 V Block batteries into the charging slot until they audibly engage.

1 to 8 batteries can be individually charged:

4 x Type C or Type D batteries in the charging slots 1 to 4, with additionally 2 x Type 9 Volt

Block batteries in the charging slots 5 and 6.

or

6 x Type AA or AAA batteries in the charging slots 1 to 4, with additionally 2 x Type 9 Volt Block batteries in the charging slots 5 and 6.

The charging process now begins. The Battery Charger has an LED for each charging slot. The LEDs of the charging slots indicate the charge state of the battery they contain.

In the first 5 seconds the Battery Charger carries out a capacity test:

The LED of the charging slot glows green: The battery capacity lies over 90 %.

The LED of the charging slot glows orange:

The battery capacity lies between 80 % 90 %. The LED of the charging slot glows red:

The battery capacity lies under 80 %.

The LED of the charging slot blinks red : The battery is not properly inserted into the charging slot or is defect.

When the battery capacity has been determined, the charging process begins.

- 4 -

Image 6
Contents All-Purpose Battery Charger TLG 1000 A1 TLG 1000 A1 Content Intended Use Technical dataSafety instructions Items suppliedInjury hazard Do not use damaged corroded batteriesCharging batteries Battery capacity lies under 80 %Commissioning Block batteries in the charging slots 5Calculating the average charging time Current time Min. =Disposal TroubleshootingCleaning Case of doubt, please contact your waste disposal centreAny way by this warranty Warranty & Service ImporterRing not carried out by our authorized service Your goods be assured