8. STARTUP & ADJUSTMENT

8. STARTUP & ADJUSTMENT

1.After plumbing and wiring are complete, close the service valve to allow startup without pressurizing the entire plumbing system. If a service valve was not installed, close all fixtures in the home. Ensure the bottom drain is closed.

2.Restore power to the Well-X1by turning on the breaker and electrical service switch (if installed). The display will illuminate.

3.The display will read "88" to test the display illumination, then a number identifying the control type (i.e. 07). This number is for factory use and may vary by model and manufacture date.

4.After a slight pause, the pump will start and the system pressure will be displayed. This number will increase as the pump runs and the tank fills.

Note: Some jet pumps may be difficult to prime, resulting in the low water cut-off activating if pressure

will not build above 10 psig. Depressing the s arrow will temporarily override the low water cut-off to allow proper priming.