9. PUMP PROTECTION AND DIAGNOSTICS

9. PUMP PROTECTION AND DIAGNOSTICS

The Well-X1continually monitors pressure, cycle time and voltage to protect the well pump. The following error codes alert the user to a potential problem, prompting service.

E1: Rapid Cycle

E2: Low Suction (low water cut-off)

E3: Voltage Protection

E5: Improper Wiring

WELL-X1ERROR CODES

When an error occurs, the display will flash a diagnostic code and emit an audible chirp.

ERROR CODE

 

POSSIBLE CAUSES AND CONTROL ACTION

 

E1: Rapid Cycle

 

Multiple cycles below a safe runtime indicate an incorrect

 

 

 

 

 

 

precharge, undersized Well-X1or waterlogged tank. Pump

 

 

 

 

continues to run.

 

 

 

 

 

 

 

E2: Low Suction

 

Pump operation below 10 psi indicates a low well level, well

 

 

 

piping leak, insufficient prime, failing pump or loose wiring.

 

 

 

 

Pump will shut down and attempt to restart every 60 minutes.

 

 

 

 

 

 

 

 

 

If line voltage varies outside a safe operating range, low or

 

 

E3: Voltage Protection

 

high, the control will run for up to two minutes to ensure water

 

 

 

 

is available, then shut the pump off until voltage is restored to

 

 

 

 

a normal range.

 

 

 

 

 

 

 

E5: Improper Wiring

 

This error indicates the LINE and LOAD wiring is reversed at

 

 

 

the Well-X1. Correct wiring to allow proper operation.

 

 

 

 

 

 

NOTE: E4 is not used with the Well-X1.

 

 

 