9. PUMP PROTECTION AND DIAGNOSTICS
The
E1: Rapid Cycle
E2: Low Suction (low water
E3: Voltage Protection
E5: Improper Wiring
WELL-X1™ ERROR CODES
When an error occurs, the display will flash a diagnostic code and emit an audible chirp.
ERROR CODE |
| POSSIBLE CAUSES AND CONTROL ACTION | ||
| E1: Rapid Cycle |
| Multiple cycles below a safe runtime indicate an incorrect |
|
|
|
| ||
|
| precharge, undersized |
| |
|
|
| continues to run. |
|
|
|
|
|
|
| E2: Low Suction |
| Pump operation below 10 psi indicates a low well level, well |
|
|
| piping leak, insufficient prime, failing pump or loose wiring. |
| |
|
|
| Pump will shut down and attempt to restart every 60 minutes. |
|
|
|
|
|
|
|
|
| If line voltage varies outside a safe operating range, low or |
|
| E3: Voltage Protection |
| high, the control will run for up to two minutes to ensure water |
|
|
|
| is available, then shut the pump off until voltage is restored to |
|
|
|
| a normal range. |
|
|
|
|
|
|
| E5: Improper Wiring |
| This error indicates the LINE and LOAD wiring is reversed at |
|
|
| the |
| |
|
|
|
|
|
NOTE: E4 is not used with the |
|
|
|
13