Tripp Lite ULTRACOPY Fax/Data Line Connection ISOFAX & ULTRAFAX Models Only, Indicator Lights

Models: ULTRABLOK ULTRACOAX ISOBLOK ISOFAX ULTRAFAX ULTRACOPY

1 12
Download 12 pages 2.18 Kb
Page 2
Image 2
Fax/Data Line Connection

Fax/Data Line Connection

(ISOFAX & ULTRAFAX Models Only)

1

Connect a phone cord directly from

 

the telephone jack to the "IN" jack of

 

your surge suppressor.

 

• Your surge suppressor must be the first item in line from the

 

telephone jack for it to protect against surges on the fax/data line.

 

• Your surge suppressor can only protect against fax/data line

 

surges if it is properly connected to a grounded AC outlet.

2

Connect a phone cord from the device to be protected to the

 

"OUT" jack of your surge suppressor.

ISOFAX models can protect TWO lines on one cable simultaneously. If you have an ISOFAX and want to protect two lines that do NOT travel through one cable, you must use "Y" splitters appropriate to your application to adapt them to your surge suppressor.

Coaxial Cable Connection

(ULTRACOAX Model Only)

1

Connect the source coaxial cable from its

 

wall jack to the "COAX IN" jack of your

surge suppressor.

• Your surge suppressor must be the first item in line from the wall jack for it to protect against surges on the coaxial cable.

Your surge suppressor can only protect against coaxial cable surges if it is properly connected to a grounded AC outlet.

2 Connect a coaxial patch cord from the device to be protected to the surge suppressor's "COAX OUT" jack.

Indicator Lights

Indicator light descriptions apply when the UPS is plugged into a wall outlet.

Protection Present (or unlabeled) (All Models)

This green LED will be lit so long as all the surge suppression components of your unit are intact and providing full protection against spikes and surges. If it is not lit, the unit has lost part of its surge suppression capabilities and should be returned for repair, though it is still usable and will provide limited surge suppression.

Line OK (Select Models Only)

This green LED lights up whenever 120V AC power is present with no wiring faults detected. It indicates that the supplied power is safe for connected equipment.

Fault (Select Models Only)

This red LED lights up if the surge suppressor detects a wiring fault. The unit can detect if the phases are reversed, the ground is missing, the receptacles are loose and other wiring faults, but cannot indicate every possible wiring problem. If this LED lights up, contact a qualified electrician to repair your wiring.

This multicolored light displays 7 separate UPS battery charge conditions. It will turn from red (low) to yellow (medium) to green (full) to show you the level of battery charge. If the light is constant, your UPS is operating from line power, and the battery is charging. If the light is flashing, your UPS is operating from battery power, and the battery is discharging. When the light flashes red, close any files you are working on and shut down your computer.

2

Page 2
Image 2
Tripp Lite Fax/Data Line Connection ISOFAX & ULTRAFAX Models Only, Coaxial Cable Connection ULTRACOAX Model Only