8. STARTUP & ADJUSTMENT (con't)

8. STARTUP & ADJUSTMENT (con't)

5.The factory cut-out (pump off) setting is 60 psig. When the pump reaches 60 psig, the Well-X1will shut the pump off. Check the plumbing for leaks and repair before continuing. If during startup the cut-out setting of 60 psig cannot be reached, read the adjustment instructions to lower the cut-out within the pump's capability.

6.Slowly open the service valve to allow the system to pressurize. The pressure may drop slightly during this process. After the valve is fully open, open the fixture closest to the Well-X1to begin drawing water from the tank.

7.When the system reaches the factory cut-in (pump on) setting of 40 psig, the pump will start. Like a traditional mechanical switch, the pressure will begin to rise, repeating the cycle. If desired, the Well-X1settings can now be adjusted as shown below.