Thank you for purchasing the BCUNI2 / BCUNI3
Charging AA and AAA Rechargeable Batteries. You can charge either one or two batteries at a time by sliding back the cover. Insert either one battery by using the right channel or two batteries by using both channels. (see diagram) again use the adjusting dial to either raise or lower the charger contacts to meet the batteries contacts. Pay attention to the polarity markings
on the channel of the charger. | ONE CELL CHARGING | TWO CELL CHARGING |
|
|
Note:
Do not mix cells type in the charging bays. Cells must be inserted in the charging bays must be the same size, capacity and chemistry. (I.e. NiCd or NiMH) The charger may malfunction with mixed cell types or capacities in the charging bays and damage the cells permanently.
LED Power Indicator. | USB PORT. (BCUNI3 ONLY) | LCD Display. |
(BCUNI2 ONLY) | The USB port allows | (BCUNI3 ONLY) |
There is a BLUE LED power | simultaneous charging of your |
|
indicator on the face of | mobile phone, MP3 |
|
Operating Instructions
Adjusting the Sliding Cover.
For small or standard batteries, just simply pull back the sliding cover. If your battery is larger, you will need to press down the release button which allows the sliding cover to extend up to 3 inches, allowing you to charge longer batteries.
Adjusting Contact Positions for Charging. By manually moving the contact adjusters left and right you are able to adjust the contacts to your desired width to accommodate the positive and negative terminals. Then with the adjusting dial you are able to raise and lower the contacts allowing the contacts to touch the positive and negative terminals.
Inserting the Desired Battery to Charge. With the sliding cover extended insert the battery into the BCUNI2 / BCUNI3, slide the battery back about 1/8 of an inch so you are able to see the contacts on the battery as well as the contacts on the charger. Manually adjust the contacts on the charger to meet the contacts on the battery. If needed adjust the height of the contacts by using the adjusting dial until the chargers contacts meet the batteries contacts.
1.
TECHNICAL SPECIFICATION
RELEASE BUTTON
CONTACT ADJUSTER
ADJUSTING DIAL
the BCUNI2. | & other handheld devices. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| USB PORT |
| |
|
|
|
|
|
POWER LED INDICATOR |
| LCD DISPLAY |
| (BCUNI2 ONLY) | The SCREEN will display the following: |
|
| (BCUNI3 ONLY) | ||||||
| Power: |
|
|
|
|
|
|
| CAPACITY/ | ||
| Blue LED indicator |
|
| CHEMISTRY | FAULT | CHARGING STATUS | |||||
|
|
|
|
|
|
|
|
|
|
| |
| Charging: |
|
|
|
|
|
|
|
|
|
|
| Flashing blue LED indicator |
|
|
|
|
|
|
|
|
| |
| Full charge: |
|
|
|
|
|
|
|
|
|
|
| Solid Blue LED indicator |
|
|
|
|
|
|
|
|
| |
| Fault: |
|
| VOLTAGE CHEMISTRY | USB ACTIVE POWER UP | ||||||
| Flashing red LED |
|
| ||||||||
|
|
| Battery Capacity and charging status: | ||||||||
| Chemistry of battery pack that is charging: | ||||||||||
| Displayed with a four bar graph that shows | ||||||||||
| Either | charging capacity status | |||||||||
| Battery Voltage: |
|
| USB Active Symbol: |
|
|
| ||||
| 1.2, 2.4, 3.6, 4.8, 6.0 or 7.2 V | This will show if the USB port is in use | |||||||||
| Fault: |
|
| Power Symbol: |
|
|
|
|
| ||
| If the battery is defective or inserted incorrectly | This show the unit has power | |||||||||
|
| 2. |
|
|
|
|
|
|
|
|
WARRANTY
Power Source: 12VDC,
Input Current: 1000mA
Output Charging Current: 1000mA max. (3.6V
USB output: 5V/ 1000mA max.
Charge Termination: 130mA max.
Timing Protection: Max. 7 hours
LCD Indication: (BCUNI3)
-Power status
-Type of battery
-Type of voltage
-Battery capacity and charging status
-Fault indication
-USB port status (BCUNI3 ONLY)
Dimension (Cover closed): L: 106mm X H: 30mm X W: 60mm
Operating Temperature: 32° F~104º F (0º C~40º C)
TROUBLESHOOTING
NOTE: It is normal for the BCUNI2 /BCUNI3 to be warm during use.
Notice
Keep the BCUNI2 / BCUNI3 dry, if it gets wet wipe it dry immediately.
Use and store it in normal temperature environments.
Handle the BCUNI2 / BCUNI3 carefully, do not drop it. Do not use the BCUNI2 / BCUNI3 if the cords become damaged.
Keep the BCUNI2 / BCUNI3 away from dust and dirt; wipe it with a cloth occasionally to keep it clean.
There are no user serviceable parts inside! Modifying or tampering with its internal components can cause a malfunction and will invalidate its warranty. If your BCUNI2 / BCUNI3 is not performing as it should during the warranty period, contact Lenmar for warranty service.
This limited warranty starts from the date of original purchase and expires 2 years thereafter. If, during this period, any part, because of manufacturing defects or workmanship fails to function properly under normal use will be repaired at no charge for parts and labor or, at our option, the product will be replaced. The following is excluded: damages from delay or loss of use of equipment, or damaged batteries, malfunctions resulting from misuse, tampering, unauthorized repairs, modifications, or accident. Package the unit and its accessories carefully using ample padding material to prevent damage in transit and ship it prepaid and insured to:
LENMAR ENTERPRISES INC. USA
4035 VIA PESCADOR
CAMARILLO, CA 93012
When sending in product for service you must first get a Return Authorization by visiting www.lenmar.com/warranty fill the out required form and our customer service reps will email you instructions on returning the item to us and issue a RETURN AUTHORIZATION NUMBER (RA) to be include on the box and any corresponding paper work. If you have any questions please call customer service at (805)
All packages should include evidence of the date of purchase. Enclose $10.00 for shipping and handling for addresses in the US and $15.00 for addresses in Canada. For outside the US and Canada, freight will vary depending upon the ship to address.
Proposition 65 Notice (California)
The following statement is required in the state of California pursuant to the settlement of an action brought by the Mateel Environmental Justice Foundation against multiple electronics and appliance manufacturers
•WARNING: Handling the cord on this product will expose you to lead, a chemical known to the state of California to cause birth defects or other reproductive harm.
Wash hands after handling.
For further information contact
Lenmar Enterprises, Inc.
Product Service Department
Phone: (800)
Visit Our Web Site at: www.lenmar.com
3. | 4. |