SPECIFICATIONS

CLEANING AND MAINTENANCE

Cleaning Burner Injector Holder and Pilot Air Inlet Hole (Cont.) Logs

SPECIFICATIONS

19

CLEANING AND

MAINTENANCE

Continued

Clean the pilot assembly also. A yellow tip on the pilot flame indicates dust and dirt in the pilot assembly. There is a small pilot air inlet hole about two inches from where the pilot flame comes out of the pilot assembly (see Figure 30). With the unit off, lightly blow air through the air inlet hole. You may blow through a drinking straw if compressed air is not available.

SPECIFICATIONS

 

Echo Valley Oak Log

 

Variable Manually-Controlled

Btu (Variable)

16,000/31,500

Type Gas

Propane/LP - Natural

Ignition

Piezo

Manifold Pressure

8.0" W.C. - 3.5" W.C.

Inlet Gas Pressure (in. of water)

 

Maximum

14" - 10.5"

Burner Tube

Primary Air Inlet Holes (Shape of Holes May Vary by Model)

Injector Holder (May Be Brass or Aluminum Depending on Model)

Minimum*

11" - 5"

Shipping Weight

38 lbs.

* For purpose of input adjustment

 

Meadowbrook Oak Log

 

Thermostatically-Controlled

Btu (Variable)

26,000/39,000

Type Gas

Propane/LP - Natural

Ignition

Piezo

Manifold Pressure

8.0" W.C. - 3.5" W.C.

Figure 29 - Injector Holder On Outlet Burner Tube

Ports/Slots

Burner Tube

Pilot Assembly

Pilot Air

Inlet Hole

Figure 30 - Pilot Inlet Air Hole

LOGS

If you remove logs for cleaning, refer to Installing Logs, pages 13 and 14, to properly replace logs.

Replace log(s) if broken or chipped (dime-sized or larger).

Inlet Gas Pressure (in. of water)

 

Maximum

14" - 10.5"

Minimum*

11" - 5"

Shipping Weight

28 lbs.

* For purpose of input adjustment

For moreLOGSManual backgroundManual backgroundManual backgroundvisit www.Manual backgroundManual backgroundManual background.comManual backgroundManual backgroundManual backgroundManual backgroundManual background

111347-01B

Page 19
Image 19
Desa LSL3124N installation manual Specifications, Logs, Cleaning And Maintenance, Continued