CLEANING AND MAINTENANCE
Cleaning Burner Injector Holder and Pilot Air Inlet Hole (Cont.) Logs
SPECIFICATIONS
19
CLEANING AND
MAINTENANCE
Continued
Clean the pilot assembly also. A yellow tip on the pilot flame indicates dust and dirt in the pilot assembly. There is a small pilot air inlet hole about two inches from where the pilot flame comes out of the pilot assembly (see Figure 30). With the unit off, lightly blow air through the air inlet hole. You may blow through a drinking straw if compressed air is not available.
SPECIFICATIONS
| Echo Valley Oak Log |
| Variable |
Btu (Variable) | 16,000/31,500 |
Type Gas | Propane/LP - Natural |
Ignition | Piezo |
Manifold Pressure | 8.0" W.C. - 3.5" W.C. |
Inlet Gas Pressure (in. of water) |
|
Maximum | 14" - 10.5" |
Burner Tube
Primary Air Inlet Holes (Shape of Holes May Vary by Model)
Injector Holder (May Be Brass or Aluminum Depending on Model)
Minimum* | 11" - 5" |
Shipping Weight | 38 lbs. |
* For purpose of input adjustment |
| Meadowbrook Oak Log |
| |
Btu (Variable) | 26,000/39,000 |
Type Gas | Propane/LP - Natural |
Ignition | Piezo |
Manifold Pressure | 8.0" W.C. - 3.5" W.C. |
Figure 29 - Injector Holder On Outlet Burner Tube
Ports/Slots
Burner Tube
Pilot Assembly
Pilot Air
Inlet Hole
Figure 30 - Pilot Inlet Air Hole
LOGS
•If you remove logs for cleaning, refer to Installing Logs, pages 13 and 14, to properly replace logs.
•Replace log(s) if broken or chipped
Inlet Gas Pressure (in. of water) |
|
Maximum | 14" - 10.5" |
Minimum* | 11" - 5" |
Shipping Weight | 28 lbs. |
* For purpose of input adjustment
For morevisit www..com