VARIABLE CONTROL

OPERATING HEATER (MANUALLY-CONTROLLED MODELS)

Lighting Instructions (Cont.)

Variable Control Operation

15

OPERATING HEATER

Continued

Note: Home owners generally prefer to operate their heater with the chimney damper closed. This will put all the heat into the room. However, there may be times you will desire the full flames of the HI heat setting but will find the heat output excessive. You can open the chimney damper (if you have one) fully or partially to release some of the heat.

Manual background WARNING: Damper handle will be hot if heater has been running.

1.STOP! Read the safety information on page 14.

2.Remove control cover log (see Figure 23).

3.Make sure equipment shutoff valve is fully open.

4.Press in and turn control knob clockwise Manual background to the OFF position.

Control Cover Log

Control Knob

Ignitor

Button

Figure 23 - Control Knob and Ignitor Button Location (Actual Logs May Vary)

5.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information, page 14. If you don’t smell gas, go to the next step.

6.Slightly depress and turn control knob counterclockwise

Manual background to the PILOT position. Keep control knob pressed in for five (5) seconds (see Figure 23).

Note: You may be running this heater for the first time after hooking up to gas supply. If so, the control knob may need to be pressed in for 30 seconds or more. This will al- low air to bleed from the gas system.

7.With control knob pressed in, press and release ignitor but- ton. This will light pilot. The pilot is attached to the burner. If needed, keep pressing ignitor button until pilot lights. Note: If pilot does not light, contact a qualified service per- son or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure, page 16.

8.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs.

Note: If pilot goes out, repeat steps 3 through 7.

9.Slightly depress and turn control knob counterclockwise

Manual backgroundC-clockwiseto the HI position. The burner should light. Set control knob to any heat level between HI and LO.

10.Replace control cover log (see Figure 23).

Ignitor Electrode

Thermocouple

Pilot Burner

(Note: Appearance of pilot assembly may vary by model.)

Figure 24- Pilot

VARIABLE CONTROL

OPERATION

The variable control valve can be set to any heat setting and flame height desired, by simply turning the control knob until that setting is attained. Even the lowest setting provides realis- tic, dancing yellow flames. Selecting higher settings produces greater heat output. This results in increased heating comfort.

Manual background WARNING: Do not operate heater between PILOT and HI positions.

Manual background CAUTION: Do not try to adjust heating levels by using the equipment shutoff valve.

For moreManual backgroundManual backgroundManual backgroundManual backgroundvisit www.Manual backgroundManual backgroundManual background.comManual backgroundManual backgroundManual backgroundManual backgroundManual background