16
OPERATING HEATER
To Turn Off Gas to Appliance
Manual Lighting Procedure
OPERATING HEATER (THERMOSTAT MODELS)
For Your Safety Read Before Lighting
Lighting Instructions
OPERATING HEATER
Continued
TO TURN OFF GAS
TO APPLIANCE
Shutting Off Heater
1.Remove control cover log (see Figure 23, page 15).
2. | Press in and turn control knob clockwise | Clockwise | to the |
| HI position. |
|
|
3. | Turn the control knob clockwise Clockwise | to the PILOT | |
| position. |
|
|
4. | Press in control knob and turn clockwise | Clockwise | to the |
| OFF position. |
|
|
5.Replace control cover log (see Figure 23, page 15).
Shutting Off Burners Only (pilot stays lit)
1.Remove control cover log (see Figure 23, page 15).
2. | Turn the control knob clockwise Clockwise to the HI position. |
3. | Press in and turn control knob clockwise Clockwise to the |
| PILOT position. |
4.Replace control cover log (see Figure 23, page 15).
MANUAL LIGHTING
PROCEDURE
1.Follow steps 1 through 6 under Lighting Instructions, page 15.
2.Depress control knob and light pilot with match.
3.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Now follow steps 9 and 10, page 15, column 2.
THERMOSTAT MODELS
FOR YOUR SAFETY READ
BEFORE LIGHTING
WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing prop- erty damage, personal injury or loss of life.
A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.
B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
•Do not try to light any appliance.
•Do not touch any electric switch; do not use any phone in your building.
•Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
•If you cannot reach your gas supplier, call the fire department.
C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service techni- cian or gas supplier. Force or attempted repair may result in a fire or explosion.
D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.
LIGHTING
INSTRUCTIONS
WARNING:
•If fireplace has glass doors, never operate this heater with glass doors closed. If you operate heater with doors closed, heat buildup inside fire- place will cause glass to burst. Make sure there are no obstructions across opening of fireplace.
•You must operate this heater with a fireplace screen in place. Make sure fireplace screen is closed before running heater.
NOTICE: During initial operation of new heater, burn- ing logs will give off a
Note: Home owners generally prefer to operate their heater with the chimney damper closed. This will put all the heat into the room. However, there may be times you will desire the full flames of the HI heat setting but will find the heat output excessive. You can open the chimney damper (if you have one) fully or partially to release some of the heat.
WARNING: Damper handle will be hot if heater has been running.