PYLE Audio 314 Functional Description, Carton Contents, Motor, Extension Cord Selection, Foreword

Page 9

MOTOR

Many Porter-Cable tools will operate on either D.C., or single phase 25 to 60 cycle A.C. current and voltage within plus or minus 5 percent of that shown on the specification plate on the tool. Several models, however, are designed for A.C. current only. Refer to the specification plate on your tool for proper voltage and current rating.

Do not operate your tool on a current on which the voltage is not within correct limits. Do not operate tools rated A.C. only on D.C. current. To do so may seriously damage the tool.

EXTENSION CORD SELECTION

If an extension cord is used, make sure the conductor size is large enough to prevent excessive voltage drop which will cause loss of power and possible motor damage. A table of recommended extension cord sizes will be found in this section. This table is based on limiting line voltage drop to 5 volts (10 volts for 230 volts) at 150% of rated amperes.

If an extension cord is to be used outdoors, it must be marked with the suffix W- A or W following the cord type designation. For example – SJTW-A to indicate it is acceptable for outdoor use.

RECOMMENDED EXTENSION CORD SIZES FOR USE WITH PORTABLE ELECTRIC TOOLS

Length of Cord in Feet

 

115V

25 Ft.

50 Ft.

100 Ft.

150 Ft.

200 Ft.

250 Ft.

300 Ft.

400 Ft.

500 Ft.

 

230V

50 Ft.

100 Ft.

200 Ft.

300 Ft.

400 Ft.

500 Ft.

600 Ft.

800 Ft.

1000 Ft.

 

 

 

 

 

 

 

 

 

 

 

 

0-2

18

18

18

16

16

14

14

12

12

 

 

 

 

 

 

 

 

 

 

 

Rating

2-3

18

18

16

14

14

12

12

10

10

 

 

 

 

 

 

 

 

 

 

3-4

18

18

16

14

12

12

10

10

8

4-5

18

18

14

12

12

10

10

8

8

Ampere

 

 

 

 

 

 

 

 

 

 

5-6

18

16

14

12

10

10

8

8

6

 

 

 

 

 

 

 

 

 

 

6-8

18

16

12

10

10

8

6

6

6

8-10

18

14

12

10

8

8

6

6

4

Nameplate

 

 

 

 

 

 

 

 

 

 

10-12

16

14

10

8

8

6

6

4

4

 

 

 

 

 

 

 

 

 

 

12-14

16

12

10

8

6

6

6

4

2

14-16

16

12

10

8

6

6

4

4

2

 

 

 

 

 

 

 

 

 

 

 

16-18

14

12

8

8

6

4

4

2

2

 

 

 

 

 

 

 

 

 

 

 

 

18-20

14

12

8

6

6

4

4

2

2

FUNCTIONAL DESCRIPTION

FOREWORD

Your Porter-Cable Trim Saw is designed for cutting trim, composition board, plywood, plastics, plexiglas, and other problem materials. Maximum depth of cut is 1-5/16" at 90° and 1-1/16" at 45° with 4-1/2" diameter blade.

CARTON CONTENTS

Contents of the packaging carton include the saw, a 3/8" wrench, a 5/32" hex wrench, a parts list, and an instruction manual.

9

Image 9
Contents Trim Saw Important Safety Instructions Table of ContentsCalifornia Proposition Safety Guidelines DefinitionsGeneral Safety Rules General Safety Rules Safety Instructions for All Saws Additional Specific Safety RulesLower Guard Safety Instructions Symbol Definition Functional Description Carton ContentsMotor Extension Cord SelectionAssembly Operation Installing Plexiglas BladeTo Change SAW Blades To Adjust Depth of CUT To Adjust for Bevel CutsTo Attach the Base Insert To Attach the RIP Guide HOW to USE the SAWCrosscutting and Bevel Cuts To Follow the Line of CUTRipping Panel CutsPocket Cuts Troubleshooting Guide Maintenance Keep Tool CleanFailure to Start Lubrication Accessories ServiceReplacement Parts Service and Repairs Brush InspectionPORTER-CABLE Limited ONE Year Warranty WarrantyCanadian PORTER-CABLE Delta Service Centers