Bryant 124A manual Guide Specifications General, Products

Page 32

124A

GUIDE SPECIFICATIONS

GENERAL

System Description

Outdoor-mounted, air-cooled, split-system air conditioner unit suitable for ground or rooftop installation. Unit consists of a hermetic compressor, an air-cooled coil, propeller-type condenser fan, and a control box. Unit will discharge supply air upward as shown on contract drawings. Unit will be used in a refrigeration circuit to match up to a packaged fan coil or coil unit.

Quality Assurance

Unit will be rated in accordance with the latest edition of ARI Standard 210.

Unit will be certified for capacity and efficiency, and listed in the latest ARI directory.

Unit construction will comply with latest edition of ANSI/ ASHRAE and with NEC.

Unit will be constructed in accordance with UL standards and will carry the UL label of approval. Unit will have c-UL approval.

Unit cabinet will be capable of withstanding Federal Test Method Standard No. 141 (Method 6061) 500-hr salt spray test.

Air-cooled condenser coils will be leak tested and pressure tested.

Unit constructed in ISO9001 approved facility.

Delivery, Storage, and Handling

Unit will be shipped as single package only and is stored and handled per unit manufacturer’s recommendations.

Warranty (for inclusion by specifying engineer)

U.S. and Canada only.

PRODUCTS

Equipment

Factory assembled, single piece, air-cooled air conditioner unit. Contained within the unit enclosure is all factory wiring, piping, controls, compressor, refrigerant charge Puronr (R-410A), and special features required prior to field start-up.

Unit Cabinet

Unit cabinet, including louvered coil guard, will be constructed of galvanized steel, bonderized, and coated with a powder coat paint.

Fans

Condenser fan will be direct-drive propeller type, discharging air upward.

AIR-COOLED, SPLIT-SYSTEM AIR CONDITIONER 124A 1-1/2 TO 5 NOMINAL TONS

Condenser fan motors will be totally enclosed, 1-phase type with class B insulation and permanently lubricated bearings. Shafts will be corrosion resistant.

Fan blades will be statically and dynamically balanced.

Condenser fan openings will be equipped with coated steel wire safety guards.

Compressor

Compressor will be hermetically sealed.

Compressor will be mounted on rubber vibration isolators.

Compressor will be covered with a sound absorbing blanket.

Condenser Coil

Condenser coil will be air cooled.

Coil will be constructed of aluminum fins mechanically bonded to copper tubes which are then cleaned, dehydrated, and sealed.

Refrigeration Components

Refrigeration circuit components will include liquid-line shutoff valve with sweat connections, vapor-line shutoff valve with sweat connections, system charge of Puronr (R-410A) refrigerant, and compressor oil.

Unit will be equipped with high-pressure switch, low pressure switch and filter drier for Puron refrigerant.

Operating Characteristics

The capacity of the unit will meet or exceed _____ Btuh at a suction temperature of _____ _F/_C. The power consumption at full load will not exceed _____ kW.

Combination of the unit and the evaporator or fan coil unit will have a total net cooling capacity of _____ Btuh or greater at conditions of _____ CFM entering air temperature at the evaporator at _____ _F/_C wet bulb and _____ _F/_C dry bulb, and air entering the unit at

_____ _F/_C.

The system will have a SEER of _____ Btuh/watt or greater at DOE conditions.

Electrical Requirements

Nominal unit electrical characteristics will be _____ v, single phase, 60 hz. The unit will be capable of satisfactory operation within voltage limits of _____ v to

_____ v.

Unit electrical power will be single point connection.

Control circuit will be 24v.

Special Features

Refer to section of this literature identifying accessories and descriptions for specific features and available enhancements.

E 2009 Bryant Heating & Cooling Systems 7310 W. Morris St. Indianapolis, IN 46231

Printed in U.S.A.

Edition Date: 02/09

Catalog No. PDS124A---07

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.

Replaces: PDS124A--- 06

32

Image 32
Contents Industry Leading Features / Benefits Product DataModel Number Nomenclature SeerPhysical Data Vapor Line Sizing and Cooling Capacity LossAccessories ThermostatsAccessory Usage Guideline YesSound Hood Charging Subcooling TXV-TYPE Expansion Device Weighted Sound PowerElectrical Data Dimensions English Dimensions SI Clearances Phase Combination RatingsFE5ANB004+UI FF1ENP030FX4CNF030 FY4ANF030Combination Ratings FF1ENP036 FY4ANF036FY4ANF042 FE4ANB006+UIFV4BNB006 Combination Ratings FY4ANF048 FY4ANB060 59000 12.50 14.50 3048424 124ANA060---C Detailed Cooling CAPACITIES# Capacity MBtuh Total Sys Sens‡ 700800 900875 10001125 FE4ANF002 FE5ANB004 FF1ENP030 FF1ENP036Cooling Indoor Capacity 1350 10501200 Detailed Cooling CAPACITIES# 1225 14001575 FE4ANB006 FE5ANB004Detailed Cooling CAPACITIES# 1600 1800FE4ANB006 FY4ANB060 FY4ANF0481750 20002250 FE4ANB006 FV4BNB006Condenser only Ratings 124ANA042--- D Guide Specifications General Products

124A specifications

The Bryant 124A is a highly regarded heating and cooling unit, well-known for its efficient performance and reliability in residential settings. This air conditioning and heating system is designed to provide optimal comfort throughout the year while integrating seamlessly into a variety of home environments.

One of the main features of the Bryant 124A is its efficiency rating. The system boasts a Seasonal Energy Efficiency Ratio (SEER) rating of up to 16, making it an energy-conscious choice for homeowners. This high efficiency not only helps reduce energy costs but also contributes to a smaller carbon footprint, aligning with environmentally friendly practices.

The Bryant 124A utilizes advanced ComfortHeat technology, which ensures even temperature distribution throughout the home. This feature minimizes hot and cold spots, allowing for a comfortable living space regardless of external weather conditions. The system is equipped with a variable speed compressor, which adjusts its operation based on the immediate cooling or heating demands, further enhancing its energy efficiency and reducing wear and tear on the system.

In terms of reliability, the Bryant 124A is built with high-quality materials designed to withstand the rigors of changing weather conditions. It comes with a robust cabinet that provides protection against corrosion, ensuring longevity and reducing maintenance needs over time. Additionally, it features a lightweight design for easier installation, making it suitable for both new constructions and retrofits.

An added advantage of the Bryant 124A is its compatibility with smart thermostats, enabling homeowners to control their heating and cooling systems remotely through mobile apps. This integration allows for customizable settings based on individual preferences and schedules, further enhancing energy savings.

The Bryant 124A is also designed with noise reduction technology, ensuring quieter operation compared to conventional systems. This makes it an ideal choice for homes where noise levels are a concern.

In summary, the Bryant 124A is a versatile and efficient heating and cooling system packed with advanced technologies and features designed to provide comfort and reliability. With its energy efficiency, durability, and smart integration, it stands out as a favored option for homeowners seeking a dependable climate control solution.