Bryant 124A manual Sound Hood

Page 6

Accessory Description and Usage (Listed Alphabetically) (Continued)

124A

10. Sound Hood

Wraparound sound reducing cover for the compressor. Reduces the sound level by about 2 dBA.

Usage Guideline:

Suggested when unit is installed closer than 15 ft (4.57 m) to quiet areas, bedrooms, etc.

Suggested when unit is installed between two houses less than 10 ft (3.05 m) apart.

11. Support Feet

Four stick-on plastic feet that raise the unit 4 in. (101.6 mm) above the mounting pad. This allows sand, dirt, and other debris to be flushed from the unit base, minimizing corrosion.

Usage Guideline:

Suggested in the following applications: Coastal installations.

Windy areas or where debris is normally circulating. Rooftop installations.

For improved sound ratings.

12. Thermostatic Expansion Valve (TXV)

Amodulating flow-control valve which meters refrigerant liquid flow rate into the evaporator in response to the superheat of the refrigerant gas leaving the evaporator.

Kit includes valve, adapter tubes, and external equalizer tube. Hard shut off types are available.

NOTE: When using a hard shut off TXV with single phase reciprocating compressors, a Compressor Start Assist Capacitor and Relay is required.

13. Time-Delay Relay

An SPST delay relay which briefly continues operation of indoor blower motor to provide additional cooling after the compressor cycles off.

NOTE: Most indoor unit controls include this feature. For those that do not, use the guideline below.

Usage Guideline:

For improved efficiency ratings for certain combinations of indoor and outdoor units. Refer to ARI Unitary Directory.

14. Winter Start Control

This control is designed to alleviate nuisance opening of the low-pressure switch by bypassing it for the first 3 minutes of operation.

Usage Guideline:

Required to achieve ARI ratings in certain equipment combinations. Refer to combination ratings.

Hard shut off TXV or LLS required in air conditioner long line applications.

Required for use on all zoning systems.

6

Image 6
Contents Industry Leading Features / Benefits Product DataModel Number Nomenclature SeerPhysical Data Vapor Line Sizing and Cooling Capacity LossAccessories ThermostatsAccessory Usage Guideline YesSound Hood Weighted Sound Power Electrical DataCharging Subcooling TXV-TYPE Expansion Device Dimensions English Dimensions SI Clearances Phase Combination RatingsFX4CNF030 FE5ANB004+UIFF1ENP030 FY4ANF030Combination Ratings FF1ENP036 FY4ANF036FE4ANB006+UI FV4BNB006FY4ANF042 Combination Ratings FY4ANF048 FY4ANB060 59000 12.50 14.50 3048424 124ANA060---C Detailed Cooling CAPACITIES# 800 Capacity MBtuh Total Sys Sens‡700 9001125 8751000 FE4ANF002 FE5ANB004 FF1ENP030 FF1ENP036Cooling Indoor Capacity 1050 12001350 Detailed Cooling CAPACITIES# 1575 12251400 FE4ANB006 FE5ANB004Detailed Cooling CAPACITIES# FE4ANB006 16001800 FY4ANB060 FY4ANF0482250 17502000 FE4ANB006 FV4BNB006Condenser only Ratings 124ANA042--- D Guide Specifications General Products

124A specifications

The Bryant 124A is a highly regarded heating and cooling unit, well-known for its efficient performance and reliability in residential settings. This air conditioning and heating system is designed to provide optimal comfort throughout the year while integrating seamlessly into a variety of home environments.

One of the main features of the Bryant 124A is its efficiency rating. The system boasts a Seasonal Energy Efficiency Ratio (SEER) rating of up to 16, making it an energy-conscious choice for homeowners. This high efficiency not only helps reduce energy costs but also contributes to a smaller carbon footprint, aligning with environmentally friendly practices.

The Bryant 124A utilizes advanced ComfortHeat technology, which ensures even temperature distribution throughout the home. This feature minimizes hot and cold spots, allowing for a comfortable living space regardless of external weather conditions. The system is equipped with a variable speed compressor, which adjusts its operation based on the immediate cooling or heating demands, further enhancing its energy efficiency and reducing wear and tear on the system.

In terms of reliability, the Bryant 124A is built with high-quality materials designed to withstand the rigors of changing weather conditions. It comes with a robust cabinet that provides protection against corrosion, ensuring longevity and reducing maintenance needs over time. Additionally, it features a lightweight design for easier installation, making it suitable for both new constructions and retrofits.

An added advantage of the Bryant 124A is its compatibility with smart thermostats, enabling homeowners to control their heating and cooling systems remotely through mobile apps. This integration allows for customizable settings based on individual preferences and schedules, further enhancing energy savings.

The Bryant 124A is also designed with noise reduction technology, ensuring quieter operation compared to conventional systems. This makes it an ideal choice for homes where noise levels are a concern.

In summary, the Bryant 124A is a versatile and efficient heating and cooling system packed with advanced technologies and features designed to provide comfort and reliability. With its energy efficiency, durability, and smart integration, it stands out as a favored option for homeowners seeking a dependable climate control solution.