Grizzly G0621 owner manual Circuit Requirements, 220V Single-Phase

Page 11

SECTION 2: CIRCUIT REQUIREMENTS

220V Single-Phase

Serious personal injury could occur if you connect the machine to the power source before you have completed the set up pro- cess. DO NOT connect the machine to the power source until instructed to do so.

Amperage Draw

The Model G0621 motor draws the following amps under maximum load:

Motor Draw

5 Amps

Circuit Requirements

We recommend connecting your machine to a dedicated and grounded circuit that is rated for the amperage given below. Never replace a circuit breaker on an existing circuit with one of higher amperage without consulting a qualified electri- cian to ensure compliance with wiring codes. If you are unsure about the wiring codes in your area or you plan to connect your machine to a shared circuit, consult a qualified electrician.

Minimum Power Supply Circuit ............. 15 Amps

Plug/Receptacle Type

Recommended Plug/Receptacle...... NEMA 6-15

Figure 1. NEMA 6-15 plug and receptacle.

G0621 Wood/Metal Bandsaw

Grounding

In the event of an electrical short, grounding reduces the risk of electric shock. The grounding wire in the power cord must be properly connected to the grounding prong on the plug; likewise, the outlet must be properly installed and grounded. All electrical connections must be made in accor- dance with local codes and ordinances.

Electrocution or fire could result if this machine is not grounded correctly or if your electrical config- uration does not comply with all applicable codes. Ensure compliance by checking with a qualified electrician!

Extension Cords

We do not recommend the use of extension cords. Instead, arrange the placement of your equipment and the installed wiring to eliminate the need for extension cords.

If you find it absolutely necessary to use an exten- sion cord at 220V with your machine:

Use at least a 14 gauge cord that does not exceed 50 feet in length!

The extension cord must also contain a ground wire and plug pin.

A qualified electrician MUST size cords over 50 feet long to prevent motor damage.

-9-

Image 11
Contents Model G0621 WOOD/METAL Bandsaw Page Table of Contents Contact Info IntroductionForeword Machine Data Sheet G0621 Wood/Metal Bandsaw Identification Safety G0621 Wood/Metal Bandsaw Additional Safety Instructions for Bandsaws Circuit Requirements 220V Single-PhaseUnpacking SetupSetup Safety Items Needed for SetupFasteners and Tools not shown Qty InventoryMain Components Figure Qty Hardware Recognition Chart Floor Load Clean UpPlacement Location Site ConsiderationsTo assemble the bandsaw AssemblyPage Dust port installation G0621 Wood/Metal Bandsaw To center track the blade Dust Collection Blade TrackingTo connect a vacuum hose Changes in the blade tension may change the blade tracking Test RunTo tension the bandsaw blade Adjusting Support BearingsTo adjust the support bearings Tensioning BladeG0621 Wood/Metal Bandsaw To adjust the upper and lower blade guides Adjusting Blade GuidesTo calibrate the pointer on the table tilt scale Adjusting Positive StopSetting Table Tilt Scale to 0˚ To set the positive stop 90˚ to the bladeTo align the fence parallel with the miter slot Aligning TableAligning Fence To align the miter slot parallel to the bandsaw bladeOperations Operation Safety Basic ControlsIrregular Cuts Workpiece Inspection WoodOverview Straight CutsPositive stop must be removed to move the table to the left Table TiltGuide Post To tilt the tableTo make a 90˚ crosscut RippingCrosscuttingTo make a rip cut Typical resawing operation ResawingTo complete a stacked cut Cutting Curves Stacked CutsTooth Style Blade Selection Wood CuttingBlade Length Blade WidthMost common causes of blade breakage are Tooth PitchBlade Care Blade BreakageTo select the correct blade TPI Blade Selection Metal CuttingTo replace the blade Blade ChangesTo calibrate the scale Scale CalibrationG1928-Bandsaw Handbook AccessoriesGrizzly Bandsaw Blades G7315-Super Heavy-Duty Mobile BaseLubricating MaintenanceCleaning ScheduleMotor & Electrical ServiceTroubleshooting Miscellaneous Cutting OperationsChecking V-Belts Accessing V-BeltsServicing V-Belts Tensioning/Replacing V-Belts To skew your fence Shimming Table Blade LeadTo shim the table Verifying Upper/Lower Wheels are Coplanar Wheel AlignmentShimming Upper Wheel Adjusting Lower WheelTo adjust the lower wheel Motor junction box wiring Electrical Component WiringWiring Diagram Breakdown Description Main Parts ListTable/Blade Guides Parts Breakdown Secondary Parts Breakdown Stand Parts Breakdown Fence Parts Breakdown Safety Labels Parts Breakdown Warranty and Returns Page Page Page