SECTION 2: CIRCUIT REQUIREMENTS
110/220V Operation
Serious personal injury could occur if you connect the machine to the power source before you have completed the set up pro- cess. DO NOT connect the machine to the power source until instructed to do so.
Amperage Draw
The Model G9743 features 110/220V motor that is prewired for 110V and draws the following amps under maximum load:
Motor Draw at 110V | 23 | Amps |
Motor Draw at 220V | 11.5 | Amps |
Circuit Requirements
We recommend connecting this machine to a dedicated circuit with a verified ground, using the circuit breaker size given below. Never replace a circuit breaker with one of higher amperage with- out consulting a qualified electrician to ensure compliance with wiring codes. If you are unsure about the wiring codes in your area or you plan to connect your machine to a shared cir- cuit, you may create a fire
110V Circuit Breaker | 25 Amps |
220V Circuit Breaker | 15 Amps |
Wiring for 220V
The Model G9743 can be rewired to operate on a 220V power source. The motor must be rewired according to the wiring diagram on the motor label. The wiring configuration can also be found on the inside of the motor wire cover, as well as on Page 39.
Plug Type
The Model G9743 comes prewired with a NEMA
2 for an example):
220V Plug & Receptacle | ||
|
|
|
|
|
|
|
|
|