Amana ASX 14 SEER Condensing Unit Specifications, ASX140181A ASX140241A ASX140301A ASX140361A

Page 6

CONDENSING UNIT SPECIFICATIONS

ASX140181A* - ASX140361A*

 

ASX140181A*

ASX140241A*

ASX140301A*

ASX140361A*

 

 

 

 

 

 

 

 

 

Cooling Capacity, BTUH

18,000

 

24,000

 

30,000

 

36,000

 

 

 

 

 

 

 

 

 

 

Compressor

 

 

 

 

 

 

 

 

R.L. Amps

9.00

 

13.4

 

12.8

 

14.1

 

L.R. Amps

48.0

 

58.3

 

64.0

 

77.0

 

Low Pressure Switch

 

 

 

 

 

 

 

 

Open

22 PSIG

22 PSIG

22 PSIG

22 PSIG

Close

50 PSIG

50 PSIG

50 PSIG

50 PSIG

High Pressure Switch

 

 

 

 

 

 

 

 

Open

610 PSIG

610 PSIG

610 PSIG

610 PSIG

Close

420 PSIG

420 PSIG

420 PSIG

420 PSIG

Condenser Fan Motor

 

 

 

 

 

 

 

 

Horsepower

1/12

 

1/12

 

1/6

 

1/4

 

F.L. Amps

0.6

 

0.6

 

1.5

 

1.6

 

Liquid Line, Inches O.D.*

3/8"

 

3/8"

 

3/8"

 

3/8"

 

Suction Line, Inches O.D.*

3/4"

 

3/4"

 

3/4"

 

7/8"

 

Refrigerant Charge

121.0

 

126.0

 

131.0

 

146.0

 

Power Supply

208/230-60-1

 

208/230-60-1

 

208/230-60-1

 

208/230-60-1

 

Minimum Circuit Ampacity(1)

11.8

 

17.4

 

17.5

 

19.2

 

Maximum Overcurrent Device(2)

20

 

30

 

30

 

30

 

Electrical Conduit Size

 

 

 

 

 

 

 

 

Power Supply (Inches)

1/2 or 3/4

1/2 or 3/4

1/2 or 3/4

1/2 or 3/4

Approximate Shipping Weight

178

 

178

 

195

 

199

 

 

 

 

 

 

 

 

 

 

ASX140421A* - ASX140[48-60]1A* / ASX140[48-60]1B*

 

 

 

 

 

 

 

 

 

 

 

 

ASX140421A*

 

ASX140481

 

ASX140481

 

ASX140601A*

 

 

 

AA/AB/AC

 

AD/B*

 

ASX140601B*

 

 

 

 

 

 

 

Cooling Capacity, BTUH

42,000

 

48,000

 

48,000

 

60,000

 

 

 

 

 

 

 

 

 

 

Compressor

 

 

 

 

 

 

 

 

R.L. Amps

17.9

 

19.8

 

19.8

 

26.4

 

L.R. Amps

112.0

 

109.0

 

109.0

 

134.0

 

Low Pressure Switch

22 PSIG

 

22 PSIG

 

22 PSIG

 

22 PSIG

 

Open

 

 

 

 

Close

50 PSIG

 

50 PSIG

 

50 PSIG

 

50 PSIG

 

High Pressure Switch

 

 

 

 

 

 

 

 

Open

610 PSIG

 

610 PSIG

 

610 PSIG

 

610 PSIG

 

Close

420 PSIG

 

420 PSIG

 

420 PSIG

 

420 PSIG

 

Condenser Fan Motor

 

 

 

 

 

 

 

 

Horsepower

1/4

 

1/4

 

1/4

 

1/4

 

F.L. Amps

1.6

 

1.6

 

1.6

 

1.6

 

Liquid Line, Inches O.D.*

3/8"

 

3/8"

 

3/8"

 

3/8"

 

Suction Line, Inches O.D.*

7/8"

 

7/8"

 

7/8"

 

7/8"

 

Refrigerant Charge

180.0

 

186.0

 

189.0

 

271.0

 

Power Supply

208/230-60-1

 

208/230-60-1

 

208/230-60-1

 

208/230-60-1

 

Minimum Circuit Ampacity(1)

24.0

 

26.4

 

26.4

 

34.6

 

Maximum Overcurrent Device(2)

40

 

40

 

40

 

60

 

Electrical Conduit Size

 

 

 

 

 

 

 

 

Power Supply (Inches)

1/2 or 3/4

 

1/2 or 3/4

 

1/2 or 3/4

 

1/2 or 3/4

 

Approximate Shipping Weight

207

 

242

 

242

 

280

 

*Up to 24' in equivalent line length

(1)Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes.

(2)Maximum Overcurrent Protection Device: MUST use Time Delay Fuses or HACR type Circuit Breaker of the same size as noted.

6

NOTE: This data is provided as a guide, it is important to electrically connect the unit and properly size fuses/ circuit breakers and wires in accordance with all national and/or local electrical codes. Use copper wire only.

Image 6
Contents Technical Manual For any injury or property damage Product IdentificationGoodman will not be responsible Should be performed only by indi Do not connect or use any device Product Design Minimum Airflow Clearance Model TypeDimensions Model Dimensions W x D x HCondensing Unit Specifications ASX140181A ASX140241A ASX140301A ASX140361AASX140181B* ASX140361B* / ASX140181C* ASX140361C ASX140181D* / ASX140421D Airflow Cooling Performance DataModel ASX140181A* / CA*F3131B6A* + TXV 17.2357 ASX140181A18.0 141Cooling Performance Data ASX140181B* / C* / D Model ASX140181B*/CA*F3636*6C19.0 362147 22.9 Outdoor Am bient Tem peratureEntering Indoor Wet Bulb Te m perature 38124.0 ASX140241AModel ASX140241A* / CA*F3636B6A* / .057 Orifice 382ASX140241B* / C Model ASX140241B* / CA*F3636*6CExpanded Performance Data ASX140301A Model ASX140301A* / CA*F3642C6A* / .063 Orifice28.8 149ASX140301B* / C Model ASX140301B*/CA*F3642*6C10.0 10.2 10.5 ASX140361A Model ASX140361A* / CA*F3642C6A* / .067 Orifice34.6 11.0ASX140361B* / C Model ASX140361B*/CA*F3642*6COutdoor Am bie nt Tem pe rature 105 115 10.5145 Model ASX140421A* / CA*F4860C6A* / .074 Orifice 12.9 ASX140421A40.0 360Model ASX140421B* / CA*F4860C6A* / .074 Orifice ASX140421B 40.011.7 Model ASX140421C*/CA*F4860*6B11.4 37.4390 ASX140421C* / D12.2 152ASX140481A* / B Model ASX140481A* / CA*F4860D6A* / .079 Orifice370 46.014.4 148ASX140481C Model ASX140481C* / CA*F4860D6A / .078 Orifice15.1 391Model ASX140601A* / CA*F4860D6A* / .088 Orifice 19.1 ASX140601A* / B56.0 394Performance Data ASX14018-601A* /ASX14048-601B 18,000 12,758 242 573Performance Data ASX14024-421B* /ASX14018-361C 460Btuh Watts Performance DataOutdoor Total Sensible Latent TVA Conditions @ 95 OD DB, 75 ID DB, 63 ID WBDiagrams ASX14018-601Wiring Is subject to change. AlwaysASX14024 ASX140481CB