Grizzly G8694, G8889 instruction manual Preparing For Use, G8695 oil level indicator

Page 9

Preparing For Use

Before using your Grizzly Air Compressor, follow these steps before the first use:

1.Remove all packing materials and any pro- tective plastic plugs from the cylinder head or oil plug.

2.Be sure the air filter is attached to the side of the cylinder head.

3.Check the oil level in the motor crankcase. For the G8694 and G8889 the oil is checked by removing the filler cap and checking to make sure the oil level is between the two marks on the end of the dipstick. For the G8695 the oil can be checked using the clear plastic sight gauge. The oil level should be close to the center of the gauge. See Figure 2.

Proper Oil Level

Fig 2. G8695 oil level indicator.

4.Make sure drain valve(s) on the air tanks is closed.

5.Make sure the power switch is in the OFF position, fully pushed in. Connect the power cord(s) to a properly protected power source.

NOTICE

The machine should never be run without a full oil reservoir. The oil provides lubrica- tion to the cylinder rings which deliver the compressed air. Severe damage to the internal parts can occur if there is not ade- quate oil flow. Check the oil level frequent- ly, and change the oil on a regular sched- ule.

Operating this equipment has the potential to propel debris into the air which can cause eye injury. Always wear safety glass- es or goggles when operating equipment. Everyday glasses or reading glasses only have impact resistant lenses, they are not safety glasses. Be certain the safety glass- es you wear meet the appropriate stan- dards of the American National Standards Institute (ANSI).

Operating this equipment has the potential for hearing damage to occur, especially if operated for a long period of time. Use ANSI (American National Standards Institute) approved ear muff or ear plugs when using this equipment. Always wear proper hearing protection, cotton balls or tissue paper in the ear canal do not provide adequate noise reduction.

 

 

 

G8694/G8695/G8889 Air Compressors

 

 

 

-8-

 

 

 

 

Image 9
Contents AIR Compressors Table Of Contents Safety Instructions For Power Tools Safety11-12 13-16 17-20 21-30 Length AMP RatingAdditional Safety Instructions For Air Compressors 110V Operation Circuit RequirementsGrounding Extension CordsCommentary Setting UP and OperatingUnpacking Site Considerations Preparing For Use G8695 oil level indicatorStart switch and gauges StartingPressure Regulator Air control lever in closed position Connecting Tools Air Control ValveMaintenance Each UseTypical location of drain cocks After First 50 Hours Every 300 HoursWeekly Symptom Possible Cause Corrective Action TroubleshootingParts List G8694/G8695 AIR Compressor G8694/G8695/G8889 Air Compressors Warranty and Returns