Grizzly H3372 Every 300 Hours Storage, When storing your air compressor fol- low these guidelines

Page 17

Every 300 Hours

 

Storage

 

 

 

After every 300 hours or 3 months of regular operation, perform the following maintenance items:

Change the compressor motor oil. Use compressor oil or a non-deter- gent 30 weight oil.

Rinse the air filter foam element in water.

Check for air leaks and correct as needed.

Clean the cylinder head fins for prop- er cooling.

Check for loose bolts or fittings.

Like all power tools, there is danger associated with operating this equipment. Accidents are frequently caused by lack of familiarity or fail- ure to pay attention. Use this machine with respect and caution to lessen the possibility of operator injury. If normal safety precautions are overlooked or ignored, serious personal injury many occur.

When storing your air compressor fol- low these guidelines:

1.Set the ON/OFF button to OFF.

2.Turn the regulator counter-clockwise to set the delivery pressure to zero.

3.Disconnect air tools or accessories.

4.Pull the safety drain valve ring to bleed excess pressure from tank. The pressure gauge for the tank should read 15-20 PSI.

5.Drain water from the tank by opening the drain valve on the bottom of the tank.

6.Close the drain valve when all the water has been released.

7.Store the air compressor in its normal operating position in a cool protected area.

NOTICE

Water will condense in the air com- pressor tank. Water left in the tank can cause the tank to weaken and corrode, increasing the risk of tank rupture.

H3372 3 HP Air Compressor

-15-

Image 17
Contents Model H3372 HP AIR CompressorPage Safety Instructions For Pneumatic Tools SafetyBefore Operating This Equipment Not avoided, will result in death or serious injuryWear Approved Hearing Protection Read this Entire Manual Before Operating the Compressor Additional Safety For Air CompressorsCommentary Introduction and SET UPUnpacking Site Placement Extension Cords Circuit Requirements220V Operation Grounding Duty Cycle Preparing for USETo start the air compressor StartingTo control the air delivery to your tool AIR ControlDelivered Pressure Air Release Pressure Regulator H3372 3 HP Air Compressor Tank Pressure RegulatorTo connect air tools to your air com- pressor Connecting ToolsBefore Each Use MaintenanceTo change the V-belt drive on your air compressor Changing V-beltWeekly After First Hours Of UseEvery 300 Hours Storage When storing your air compressor fol- low these guidelinesProblem Cause Action TroubleshootingFaulty Model H3372 3 HP Air Compressor Description Ring Handle Warranty and Returns Warranty Card BOX BELLINGHAM, WA