CIRCUIT REQUIREMENTS

220V Operation

 

Grounding

 

 

 

Wiring:

The Model H3372 3 HP Air Compressor is wired for 220V operation.

Amperage Draw

The Model H3372 has a 3 HP motor and draws the following amperage.

H3372 Motor

18 Amps

Circuit Breaker Requirements

Install your air compressor on a dedicated circuit to reduce the possibility of overload- ing the circuit and tripping the circuit break- er. However, if an unusual load does not exist, and the circuit breaker still trips, have the circuit inspected by a qualified electri- cian. Never use a larger circuit breaker than stated below, or you will increase the risk of fire.

Circuit Breaker

20 Amp Double Pole

In the event of an electrical short, ground- ing reduces the risk of electric shock by providing a path of least resistance to dis- perse electric current. These machines are equipped with power cords having an equipment-grounding conductor. See Figure 1. The outlet must be properly installed and grounded in accordance with all local codes and ordinances.

Figure 1. Ground plug configuration.

Extension Cords

If you find it necessary to use an extension cord with your compressor, make sure the cord is rated Standard Service (grade S) or better. The extension cord must also con- tain a ground wire and plug pin. Always repair or replace extension cords when they become worn or damaged.

Overheating, short circuit and fire damage will result form inadequate wiring. Follow the guidelines in this section.

Potential for electrical shock haz- ard, this equipment must be grounded. Verify that any existing electrical outlet and circuit you use is actually grounded.

-6-

H3372 3 HP Air Compressor

Image 8
Contents HP AIR Compressor Model H3372Page Safety Safety Instructions For Pneumatic ToolsBefore Operating This Equipment Not avoided, will result in death or serious injuryWear Approved Hearing Protection Additional Safety For Air Compressors Read this Entire Manual Before Operating the CompressorIntroduction and SET UP CommentaryUnpacking Site Placement Extension Cords Circuit Requirements220V Operation Grounding Preparing for USE Duty CycleStarting To start the air compressorTo control the air delivery to your tool AIR ControlDelivered Pressure Air Release Tank Pressure Regulator Pressure Regulator H3372 3 HP Air CompressorConnecting Tools To connect air tools to your air com- pressorMaintenance Before Each UseChanging V-belt To change the V-belt drive on your air compressorAfter First Hours Of Use WeeklyWhen storing your air compressor fol- low these guidelines Every 300 Hours StorageTroubleshooting Problem Cause ActionFaulty Model H3372 3 HP Air Compressor Description Ring Handle Warranty and Returns Warranty Card BOX BELLINGHAM, WA