Grizzly G0465, G470, G0468 Service, Troubleshooting, Symptom Possible Cause Possible Solution

Page 19

SECTION 6: SERVICE

This section is provided for your convenience—it is not a substitute for the Grizzly Service Department. If you need help troubleshooting, replacing parts, or you are unsure of how to perform the procedures in this section, then feel free to call our Technical Support at (570) 546-9663.

Troubleshooting

Symptom

Possible Cause

Possible Solution

 

 

 

 

 

Motor will not start.

1.

Tank already pressurized.

1.

Motor will not start if tank

 

 

 

 

is fully pressurized.

 

2.

Thermal overload switch

2.

Wait for motor to cool.

 

 

has tripped.

 

 

 

3.

Low voltage.

3.

Check power line for

 

 

 

 

proper voltage.

 

4.

Short circuit in motor or

4.

Inspect all connections on

 

 

cord, or loose connec-

 

motor for loose or shorted

 

 

tions.

 

terminals or worn insula-

 

 

 

 

tion.

 

5.

Incorrect fuses or circuit

5.

Install correct fuses or cir-

 

 

breakers in power line.

 

cuit breakers.

 

6.

Pressure switch is bad.

6.

Replace the pressure

 

 

 

 

switch.

 

 

 

 

 

Motor fails to develop

1.

Power line overloaded

1.

Reduce load on power

full power (output of

 

with lights, appliances,

 

line.

motor decreases rapidly

 

and other motors.

 

 

with decrease in volt-

2.

Undersized wires or cir-

2.

Increase wire sizes or

age at motor terminals).

 

cuits too long.

 

reduce length of the cir-

 

 

 

 

cuit.

 

 

 

 

 

Motor overheats and

1.

Cooling fins dirty.

1.

Clean cylinder fins and

thermal overload turns

 

 

 

motor area.

motor OFF.

2.

Air filter clogged.

2.

Inspect and clean air filter.

 

3.

Compressor is running

3.

Do not use air tools with

 

 

too long without a break.

 

CFM needs that exceed

 

 

 

 

the compressor CFM rat-

 

 

 

 

ing.

 

4.

Air circulation through the

4.

Clean out motor to pro-

 

 

motor restricted.

 

vide normal air circula-

 

 

 

 

tion.

 

 

 

 

 

Model G0464/G0465/G0467/G0468/G0470 Air Compressors

-17-

Image 19
Contents AIR Compressor Page Table of Contents Foreword Contact Info IntroductionMachine Data Sheet Mation about proper operation of the equipment SafetyModel G0464/G0465/G0467/G0468/G0470 Air Compressors Additional Safety Instructions For Air Compressors 110V Operation Circuit RequirementsGrounding To assemble the air compressor SET UPAssembly UnpackingPlacement Operations Operation Safety StartingTo start the air compressor To control the air supply to your tool Line Pressure RegulationTo connect air tools to your air com- pressor Connecting ToolsStorage When storing your air compressor, fol- low these guidelinesSchedule MaintenanceTo drain the tank Pressure Safety ValveTo check the pressure safety valve Draining TankTroubleshooting ServiceSymptom Possible Cause Possible Solution See Check Valve Changing OilTo find air leaks Fixing Air LeaksPressure switch cover Pressure SwitchG0464 Parts Breakdown Description G0464 Parts ListG0465 Parts Breakdown G0465 Parts List G0467 Parts Breakdown REF Description G0467 Parts ListG0468 Parts Breakdown G0468 Parts List G0470 Parts Breakdown G0470 Parts List Warranty and Returns Warranty Card BOX BELLINGHAM, WA Name Street CityStateZip