Grizzly G0465, G470, G0468, G0467 instruction manual Pressure Switch, Pressure switch cover

Page 23

Pressure Switch

The pressure switch has been factory set for the highest PSI that is safe for this compressor.

The pressure switch ensures the pump will shut OFF when the air compressor tank reaches maximum PSI.

NOTICE

This air compressor has been factory set to turn ON and OFF at the proper PSI range. Only attempt to adjust the pressure regulator if your air com- pressor does not reach, or pressur- izes beyond the proper PSI level.

To adjust the pressure switch:

1.Unplug the air compressor from the power supply.

2.Make sure the compressor switch is in the OFF position.

3.Drain the pressure from the tank.

4.Remove the black AUTO/OFF switch cover (Figure 15) by removing the screw in the recess of the cover. Pull the black cover up and set it aside.

Figure 15. Pressure switch cover.

5.Turn the black plastic pressure adjust- ment screw (Figure 16) a half turn clockwise to increase the tank pressure and a half turn counterclockwise to decrease the pressure.

Figure 16. Pressure adjustment screws.

6.Adjust the metal pressure adjustment screw to change how low the pressure can drop before the motor turns ON.

7.Connect the compressor to the power supply and start the compressor. If the compressor does not automati- cally turn OFF at 120 PSI, flip the ON/ OFF switch to OFF before the pres- sure reaches 125 PSI.

8.If the PSI level still needs adjustment, repeat Steps 1–7.

9.Replace the cover when the proper adjustments have been completed.

Model G0464/G0465/G0467/G0468/G0470 Air Compressors

-21-

Image 23
Contents AIR Compressor Page Table of Contents Foreword Contact Info IntroductionMachine Data Sheet Mation about proper operation of the equipment SafetyModel G0464/G0465/G0467/G0468/G0470 Air Compressors Additional Safety Instructions For Air Compressors 110V Operation Circuit RequirementsGrounding To assemble the air compressor SET UPAssembly UnpackingPlacement To start the air compressor Operation Safety StartingOperations To control the air supply to your tool Line Pressure RegulationTo connect air tools to your air com- pressor Connecting ToolsStorage When storing your air compressor, fol- low these guidelinesSchedule MaintenanceTo drain the tank Pressure Safety ValveTo check the pressure safety valve Draining TankSymptom Possible Cause Possible Solution ServiceTroubleshooting See Check Valve Changing OilTo find air leaks Fixing Air LeaksPressure switch cover Pressure SwitchG0464 Parts Breakdown Description G0464 Parts ListG0465 Parts Breakdown G0465 Parts List G0467 Parts Breakdown REF Description G0467 Parts ListG0468 Parts Breakdown G0468 Parts List G0470 Parts Breakdown G0470 Parts List Warranty and Returns Warranty Card BOX BELLINGHAM, WA Name Street CityStateZip