Grizzly G0464 instruction manual Line Pressure Regulation, To control the air supply to your tool

Page 14

6.Close the drain valve (Figure 5) to allow the tank to build up pressure.

Figure 5. Drain valve.

7.Check the tank pressure gauge (Figure 6) to see that the tank pressure climbs to approximately 115-120 PSI (around 8 BAR), then automatically turns OFF.

Note: If the compressor does not auto- matically turn OFF at 120 PSI (115 PSI for the Model G0468), flip the ON/ OFF switch to OFF before the pres- sure reaches the maximum PSI shown on Page 3. See Pressure Switch on Page 21 to adjust the automatic shut- off.

Tank

Line

Pressure

Pressure

Figure 6. Pressure gauges.

Line Pressure Regulation

The tank pressure is displayed on the left pressure gauge, and the air to be deliv- ered to the tool (line pressure) is displayed on the right pressure gauge, shown in Figure 6.

The air tool that you attach to the air compressor should have a preferred PSI operating level. Set the pressure to be delivered to the tool according to the required level of the tool.

To control the air supply to your tool:

1.Adjust the air control knob, shown in Figure 7, to set the PSI that will be delivered to your tool. Turn the knob clockwise to increase the pressure or counterclockwise to decrease the pres- sure.

Air Control

Knob

Lock Ring

Figure 7. Tool air control knob.

2.Rotate the lock ring shown in Figure 7 against the bottom of the air control knob to prevent changes in the air pres- sure.

-12-

Model G0464/G0465/G0467/G0468/G0470 Air Compressors

Image 14
Contents AIR Compressor Page Table of Contents Introduction Foreword Contact InfoMachine Data Sheet Safety Mation about proper operation of the equipmentModel G0464/G0465/G0467/G0468/G0470 Air Compressors Additional Safety Instructions For Air Compressors Circuit Requirements 110V OperationGrounding Unpacking SET UPAssembly To assemble the air compressorPlacement To start the air compressor Operation Safety StartingOperations Line Pressure Regulation To control the air supply to your toolConnecting Tools To connect air tools to your air com- pressorWhen storing your air compressor, fol- low these guidelines StorageMaintenance ScheduleDraining Tank Pressure Safety ValveTo check the pressure safety valve To drain the tankSymptom Possible Cause Possible Solution ServiceTroubleshooting See Changing Oil Check ValveFixing Air Leaks To find air leaksPressure Switch Pressure switch coverG0464 Parts Breakdown G0464 Parts List DescriptionG0465 Parts Breakdown G0465 Parts List G0467 Parts Breakdown G0467 Parts List REF DescriptionG0468 Parts Breakdown G0468 Parts List G0470 Parts Breakdown G0470 Parts List Warranty and Returns Warranty Card Name Street CityStateZip BOX BELLINGHAM, WA