Grizzly G0464 instruction manual Circuit Requirements, 110V Operation

Page 9

SECTION 2: CIRCUIT

REQUIREMENTS

110V Operation

Serious personal injury could occur if you connect the machine to the power source before you have com- pleted the set up process. DO NOT connect the machine to the power source until instructed to do so.

Amperage Draw

The motors on the air compressors will draw the following amps:

G0464 Motor Draw

...................... 8

Amps

G0465 Motor Draw

...................... 8

Amps

G0467 Motor Draw

..................14.5

Amps

G0468 Motor Draw

...................... 8

Amps

G0470 Motor Draw

14

Amps

Circuit Requirements

Only connect your machine to a cir- cuit that meets the requirements below. Always check to see if the wires and circuit breaker in your circuit are capable of handling the amperage draw from your machine, as well as any other machines that could be operating on the same cir- cuit. If you are unsure, consult a qualified electrician.

Model G0464, G0465, G0468 Minimum

Circuit Requirement

15 Amp

Model G0467, G0470 Minimum Circuit

Requirement

20 Amp

Plug/Receptacle Type

Plug Type ..............NEMA 5-15 (Figure 1)

Figure 1. Typical type 5-15 plug and

receptacle.

This machine must have a ground prong in the plug to help ensure that it is grounded. DO NOT remove ground prong from plug to fit into a two- pronged outlet! If the plug will not fit the outlet, have the proper outlet installed by a qualified electrician.

Model G0464/G0465/G0467/G0468/G0470 Air Compressors

-7-

Image 9
Contents AIR Compressor Page Table of Contents Foreword Contact Info IntroductionMachine Data Sheet Mation about proper operation of the equipment SafetyModel G0464/G0465/G0467/G0468/G0470 Air Compressors Additional Safety Instructions For Air Compressors 110V Operation Circuit RequirementsGrounding Assembly SET UPUnpacking To assemble the air compressorPlacement Operation Safety Starting OperationsTo start the air compressor To control the air supply to your tool Line Pressure RegulationTo connect air tools to your air com- pressor Connecting ToolsStorage When storing your air compressor, fol- low these guidelinesSchedule MaintenanceTo check the pressure safety valve Pressure Safety ValveDraining Tank To drain the tankService TroubleshootingSymptom Possible Cause Possible Solution See Check Valve Changing OilTo find air leaks Fixing Air LeaksPressure switch cover Pressure SwitchG0464 Parts Breakdown Description G0464 Parts ListG0465 Parts Breakdown G0465 Parts List G0467 Parts Breakdown REF Description G0467 Parts ListG0468 Parts Breakdown G0468 Parts List G0470 Parts Breakdown G0470 Parts List Warranty and Returns Warranty Card BOX BELLINGHAM, WA Name Street CityStateZip