Harbor Freight Tools 98733 operating instructions To Attach An Air Connector

Page 8

ponents, such as a connector and quick coupler, will make operation more efficient, but are not required.

WARNING! To prevent serious

injury from accidental operation:

Do not install a female quick coupler on the tool. Such a coupler contains an air valve that will allow the air tool to retain pressure and operate accidentally after the air supply is disconnected.

Note: Air flow, and therefore tool perfor- mance, can be hindered by under- sized air supply components.

3.The air hose must be long enough to reach the work area with enough extra length to allow free movement while working.

4.Close the in-line safety valve be- tween the compressor and the tool.

5.Turn on the air compressor according to the manufacturer’s directions and allow it to build up pressure until it cycles off.

6.Adjust the air compressor’s output regulator so that the air output is enough to properly power the tool, but the output will not exceed the tool’s maximum air pressure at any time. Adjust the pressure gradually, while checking the air output gauge to set the right pressure range.

7.Inspect the air connections for leaks. Repair any leaks found.

8.If the tool will not be used at this time, turn off and detach the air supply and safely discharge any residual air pressure.

Note: Residual air pressure should not be present after the tool is disconnected from the air supply. However, it is a good safety measure to attempt to discharge the tool in a safe fashion after disconnecting to ensure that the tool is disconnected and unpowered.

To Attach An Air Connector:

1.Attach a 1/4” Connector (not included) to the Air Plug (83) on the Nailer.

2.Wrap about 3” of pipe thread seal tape (not included) onto threads of the Connector before attaching it to the Air Plug.

3.Connect the 3/8” air source hose to the Nailer.

4.Set the air pressure on compressor to 70 to 120 PSI operating pressure. Do not exceed 120 maximum PSI.

5.Check air connection for leaks. If any are present, disconnect the Nailer from air source hose.

Rev 09l

SKU 98733

For technical questions, please call 1-800-444-3353.

Page 8

Image 8
Contents Framing Nailer Safety Alert Symbol and Signal Words Save This ManualGeneral Work areaPersonal safety Tool use and careService Air sourceSymbol Definitions Specific Safety InstructionsMin Ft-lbVibration Precautions Initial Tool Set Up Assembly SpecificationsFunctional Description Air SupplyTo Attach An Air Connector Testing the Single Sequential Safety Trip Mechanism Operating InstructionsOperating Framing Nailer Operating Framing NailerLoading Nails Clearing Jams User-Maintenance Instructions Cleaning, Maintenance, LubricationTroubleshooting Problem Possible Causes Likely SolutionsParts List Assembly Diagram Limited 1 Year warranty