SPECIFICATIONS
Air Pressure | ||
Range | ||
| ||
Maximum Air | 120 PSI | |
Pressure | ||
| ||
Air Inlet | 1/4” | |
| 120 1/2” Crown Flooring Staples | |
Fastener | Length: | |
Gauge: 15 1/2 Ga | ||
Capacity and | ||
100 “L” or “T” Type Flooring Cleats | ||
Size Range | ||
Length: | ||
| ||
| Gauge: 16 Ga | |
Air | 4 SCFM @ 90 PSI | |
Consumption | ||
| ||
Safety Trigger | Slugging Actuation Only | |
(No Safety) | ||
| Wrench Set | |
| Slugging Hammer | |
Accessories | Air Coupler Adapter | |
| Air Tool Oil Dropper | |
| Spare Base Plate |
refer to the Assembly Diagram near the end of this manual.
•This tool may be shipped with the Arm (80) detached from the main body. If so, follow these instruc- tions:
Arm (80)
Nut (70) and
Washer (71)
Bracket (72)
Handle (69)
Figure A
UNPACKING
When unpacking, check to make sure that the item is intact and undamaged. If any parts are missing or broken, please call Harbor Freight Tools at the number shown throughout the manual as soon as possible.
•This air tool may be shipped with a protective plug covering the air inlet. Remove this plug before set up.
ASSEMBLY
Read the ENTIRE IMPORTANT SAFETY INFORMATION section at the beginning of this manual including all text under subheadings therein before set up or use of this product.
Note: For additional information regarding the parts listed in the following pages,
1.Set the Arm against the Handle (69) and slide the Brackets (72) through the Arm holes slots and holes.
Thread Washers (71) and Nuts (70) over ends of Brackets.
See Figure A.
2.
Air Supply Setup
TO PREVENT
EXPLOSION:
Use only clean, dry, regulated, compressed air to power tool. Do not use oxygen, carbon dioxide, combustible gases, or any other bottled gas as a power source for tool.
REV 08j; 09c; 09i
SKU 99640 | For technical questions, please call | Page 7 |