Harbor Freight Tools 67450 General Operating Instructions, Between 3/4 and 1 Long, Nails

Page 14

(88). The Platform can be adjusted up

5. Swing the Canister Cover (89) closed.

and down to use various lengths of nails

Then, close the Catch (64). Make sure

from 3/4” to 1-3/4”:

the Latch closes securely. If it does not

A. Between 3/4” and 1” Long

engage, the nail head is not in the slot in

Nails

the upper portion of the Feed Hook (50)

(Use top setting).

and nail shank is not in the feeder.

B. Between 1” and 1-1/4” Long

 

Nails

 

(Use middle setting).

 

C. Between 1-1/4” and 1-3/4”

 

Long Nails

 

(Use bottom setting).

 

Latch (68)

 

Catch

Canister

(64)

Cover

 

(89)

Canister (82)

Canister

Cover

(89)

Feed

Nails

Hook

 

 

(50)

 

 

Adjuster Plate

SHINGLE SPACING

Screw

Bracket

 

(79)

 

(80)

 

BOTTOM VIEW

6.To adjust the Shingle Bracket: The Bracket (79) controls roof shingle spacing. To adjust the Bracket to work with a particular width of shingles, use the accessory Hex Wrench to loosen the Screw (80) on the Bracket. Slide the Bracket to the desired spacing. Then, retighten the Screw.

General Operating Instructions

1.

Before each use, test the Tool as

 

directed in the earlier section.

2.

If an automatic oiler is not used, add

 

a few drops of Pneumatic Tool Oil into

Canister (82)

(86)

the tool’s airline connection before use.

Add a few drops more after each hour of

3.Turn the Adjuster Nut (88) clockwise to raise the Adjuster Plate (86) until its edge aligns with the embossed nail size markings on the inside wall of the Canister.

4.Place a coil of Nails around the Adjuster Plate (86) in the Nail Canister (82). See photo, above.

 

continual use.

3.

Keep all moving parts free from dirt, tar,

 

and debris. Clean and oil all moving

 

parts before each use.

4.

Attach the Nailer to the air supply at the

 

Air Inlet (93). Start your compressor and

 

check the pressure, making sure it is set

REV 10d

Page 14

For technical questions, please call 1-800-444-3353.

SKU 67450

Image 14
Contents For technical questions or replacement parts, please call Gauge industrial Roofing nailerSave This Manual Safety Alert Symbol and Signal WordsSymbol Property or statement For technical questions, please callWork area Personal safetyGeneral Air source ServiceTool use and care Specific Safety Instructions Vibration Precautions For technical questions, please call Unpacking Functional Description Initial Tool Set Up AssemblySpecifications Injury from accidental operation Air SupplyRecommended Air Line Components For technical questions, please call SKU For technical questions, please call Trigger Installation Sequential operation Contact Safety Trip Bump Fire Mechanism Testing Procedure Work Piece and Work Area Set UpContact Safety Trip Bump Fire Mechanism Definition Operating InstructionsLoading the Tool Single Sequential Safety Trip Mechanism DefinitionSingle Sequential Safety Trip Mechanism Testing Procedure To prevent serious injury From accidental operationBetween 3/4 and 1 Long Use top settingGeneral Operating Instructions NailsDo not exceed the tool’s maximum air Accessory failure, resultingInjury Pressure ratingUser-Maintenance Instructions Clearing JamsTroubleshooting Problem Possible Causes Likely SolutionsParts List Please Read the Following CarefullyAssembly Diagram Record Product’s Serial Number HereLimited 1 Year warranty