or worn, have the tool repaired by a qualified service technician.
3.Replace the coil of nails into the Roofing
Nailer. Close Canister Cover (89) and Catch (64) securely. Then reconnect air hose to the tool.
4.Test fire nailer into a piece of scrap wood repeatedly to test for proper operation. If nailer does not function properly, have tool serviced by a qualified technician.
Troubleshooting
Problem |
| Possible Causes |
| Likely Solutions |
Insufficient | 1. | Incorrect tool depth setting. | 1. | Adjust depth setting, if available. |
fastener depth. | 2. Not enough air pressure. | 2. | Check for loose connections and make sure that air | |
|
|
|
| supply is providing adequate air pressure (PSI) to the |
|
|
|
| tool’s air inlet. Do not exceed maximum air pressure. |
| 3. | Incorrect lubrication or not | 3. | Lubricate using air tool oil and grease according to |
|
| enough lubrication. |
| directions. |
| 4. | Blocked air inlet screen (if | 4. | Clean air inlet screen of buildup. |
|
| equipped). |
|
|
| 5. | Mechanism contaminated. | 5. | Have qualified technician clean and lubricate |
|
|
|
| mechanism. Install |
|
|
|
| Initial Set Up: Air Supply. |
Fasteners drive | 1. | Incorrect tool depth setting. | 1. | Adjust depth setting, if available. |
too deeply. | 2. Too much air pressure. | 2. | Reduce air supply pressure (PSI). | |
Tool cycles | 1. Jammed fastener. | 1. | Clear jammed fastener according to Clearing Jams | |
without firing |
|
|
| instructions. |
fastener. | 2. | Tool empty. | 2. | Fill with correct fasteners. |
| 3. | Incorrect fasteners used. | 3. | Empty, then load with correct fasteners. |
| 4. | Magazine dirty or not | 4. | Clean and lubricate magazine and pusher. |
|
| lubricated properly. |
|
|
5.Insufficient air flow.5. Check for loose connections and make sure that air supply is providing enough air flow (CFM) and pressure
(PSI) to the tool’s air inlet. Do not exceed maximum air pressure.
Frequent | 1. | Incorrect fastener type. | 1. | Confirm fastener diameter, type, length, angle, and | |
jamming. |
|
|
| collation type. Correct as needed. | |
| 2. | Safety is stuck. | 2. | Clean and lubricate with oil so safety moves freely | |
Severe air | 1. | 1. | Check for incorrect alignment and uneven gaps. If | ||
leakage. |
| components. |
| ||
(Slight air |
|
|
| before use. | |
leakage | 2. | Loose housing. | 2. | Tighten housing assembly. If housing cannot tighten | |
is normal, |
|
|
| properly, internal parts may be misaligned. | |
especially on |
|
| 3. | Replace damaged components. | |
older tools.) | 3. | Damaged valve or housing. | |||
4. | Clean or replace valve assembly. | ||||
| |||||
| 4. | Dirty, worn or damaged valve. |
|
|
Follow all safety precautions whenever diagnosing or servicing the tool. Disconnect air supply before service.
REV 10d |
|
|
SKU 67450 | For technical questions, please call | Page 17 |