Greenheck Fan QEI-L, QEID manual Roof Upblast & Spark Resistant Construction

Page 13

Roof Upblast & Spark Resistant Construction

Roof Upblast

Models QEI-I/II sizes 9 through 54 and model QEID sizes 12 through 54, are available in roof upblast configuration. The roof upblast configuration is ideal for exhausting contaminants away from a building to prevent roof damage and re-entrainment of exhaust air. Both QEI-I/II roof upblast models have the high temperature UL rating and can be used for emergency smoke exhaust applications.

Standard construction includes a fully-welded heavy- gauge curb cap to eliminate leaks, a butterfly damper section for backflow prevention, and a windband section to protect the butterfly dampers from debris. A complete line of roof curbs is available for mounting to a roof deck.

Spark Resistant Construction

Greenheck mixed flow fans are available with spark resistant designs suitable for applications that involve flammable particles, fumes or vapors. Spark resistant construction options adhere to guidelines defined within AMCA Standard 99-0401-10.

 

 

The fan wheel is constructed of a

 

 

nonferrous material (aluminum).

QEI-I/II

Spark B

A non-ferrous (aluminum) bearing

 

 

cover surrounds the driven bearing,

 

 

shielding it from the airstream.

 

 

 

 

 

The inlet cone is constructed of

QEI-I/II

 

non-ferrous material (aluminum).

Spark C

A nonferrous (aluminum) bearing

QEI-L

 

cover surrounds the driven bearing

 

 

 

 

shielding it from the airstream.

 

 

 

13

Image 13
Contents Mixed Flow Fans Mixed Flow Fans Quiet & Efficient, InlineModel Number Nomenclature Standard ConstructionMaintenance / Serviceable Construction Advantages Value Added FeaturesQuality Assurance Test Electrostatic Powder CoatingsField Rotatable Housing / Compact Size Inlet and Outlet Sound Power LevelsSlip-Fit Duct Connections AutoCAD and 3-D Revit ModelsMixed Flow Axial/Centrifugal Hybrid Design & PerformanceSound and Efficiency Airflow ProfilesSound Power versus Sound Pressure Wheel CharacteristicsBelt Drive Fan Class Direct Drive Percent Wheel WidthSound Vault Housing Radiated Sound Enclosure Optional FeaturesWhy use a Sound Vault? Zinc Advantage Optional Two-coat Paint SystemCertifications & Listings Belt Drive Advantages Belt Drive versus Direct DriveDirect Drive Advantages Tubular Centrifugal Fan QEI-I Mixed Flow FanQEI-I/II Sizes 9-27 and all QEI-L Belt Drive Mounting ConfigurationsQEI-I/II Sizes Roof Upblast Roof Upblast & Spark Resistant ConstructionSpark Resistant Construction Availability AccessoriesExploded View Direct Drive Selection Charts 870 RPM 60 Hz Qeid Dimensional DataQEI QEI Dimensional DataPerformance Data QEI-9 Class25 kW 381 mm55 kg QEI-12 Class I & QEI-L73 kg 82 kg QEI-12 Class464 mm QEI-15 Class I & QEI-L64 kg 100 kg QEI-15 Class508 mm QEI-16 Class I & QEI-L109 kg QEI-16 Class565 mm QEI-18 Class I & QEI-L87 kg 118 kg141 kg QEI-18 Class622 mm QEI-20 Class I & QEI-L105 kg 163 kg QEI-20 Class686 mm QEI-22 Class I & QEI-L123 kg 168 kg191 kg QEI-22 Class762 mm QEI-24 Class I & QEI-L182 kg 213 kg55 kW QEI-24 Class249 kg 838 mm QEI-27 Class I & QEI-L214 kg 245 kg304 kg QEI-27 Class75 kW QEI-30 Class I & QEI-L927 mm 286 kg454 kg QEI-30 Class1022 mm QEI-33 Class I & QEI-L332 kg 449 kg544 kg QEI-33 Class1130 mm QEI-36 Class I & QEI-L409 kg 635 kg QEI-36 Class1245 mm QEI-40 Class680 kg 862 kg 1378 mm QEI-44 Class907 kg 1043 kg 1524 mm QEI-49 Class1089 kg 1406 kg 11 kW1676 mm QEI-54 Class1315 kg 1633 kg 1854 mm QEI-60 Class1588 kg 1905 kg Model QEI-L, QEI-I/II and Qeid Specifications