Woodstock W1802 owner manual Symptom Possible Cause Possible Solution

Page 17

Model W1802 2 QT. Professional Spray Gun

Symptom

Possible Cause

Possible Solution

Excessive over-

1.

Fluid pressure too high.

1.

Reduce fluid pressure.

spray.

2.

Gun is too far from surface.

2.

Keep gun at recommended

 

 

 

 

distance.

 

3.

Spraying too fast.

3.

Slow down and maintain

 

 

 

 

consistent, even parallel

 

 

 

 

stroke.

 

 

 

 

 

Unable to control

1.

Pattern adjustment screw is

1.

Clean or replace.

spray fan.

 

not seating properly.

 

 

 

2.

Atomizing cap is loose.

2.

Tighten atomizing cap.

 

 

 

 

 

Runs and sags.

1.

Damaged seal.

1.

Replace damaged seals.

 

 

 

 

 

Material leaks from

1.

Cap not secure.

1.

Tighten.

cup.

2.

Cup not tight on gun body.

2.

Tighten.

 

3.

Leaking from cap vent hole.

3.

Hold gun upright do not

 

 

 

 

tilt.

 

 

 

 

 

Material leaks from

1.

Fluid tip loose.

1.

Tighten.

gun.

2.

Dry or damaged seals.

2.

Replace seals.

 

3.

Excessive pressure.

3.

Reduce pressure.

 

 

 

 

 

Thick dimpled fin-

1.

Holding gun too close to sur-

1.

Spray at recommended dis-

ish aka "Orange

 

face.

 

tance.

Peel."

2.

Inlet air pressure too low.

2.

Check inlet air pressure.

 

3.

Material not properly mixed.

3.

Follow manufacturer's

 

 

 

 

instructions.

 

4.

Surface is dirty or oily.

4.

More surface prep is

 

 

 

 

required.

 

 

 

 

 

Dry Spray.

1.

Inlet air pressure too high.

1.

Lower inlet air pressure.

 

2.

Gun too far from surface.

2.

Keep gun at recommended

 

 

 

 

distance.

 

3.

Gun stroke too fast.

3.

Slow down and maintain

 

 

 

 

consistent even parallel

 

 

 

 

stroke.

 

 

 

 

Gun leaks from

1.

Debris will not let the needle

1. Clean or replace both.

fluid tip.

 

seat with the fluid tip.

 

 

 

 

 

 

 

Contaminated

1.

Water or oil in the air line.

1.

Install an in-line air filter.

paint.

 

 

2.

Replace air line.

 

 

 

 

 

-15-

Image 17
Contents QT. Professional Spray GUN SET Page Before Operating This Equipment SafetySafety Instructions for Pneumatic Tools Always USE Safety Glasses Disconnect Compressed AIR Additional Safety Instructions for Spray GunsWoodstock Technical Support W1802 SpecificationsIntroduction Inventory SetupUnpacking Installing fluid hose AssemblyControls Spraying OperationsOverlap technique Set up for vertical spray stroke With horizontal fan pattern AdjustmentsCleaning Cleaning & Lubrication Disassembly for cleaning Lubrication points LubricationTroubleshooting Symptom Possible Cause Possible Solution W1802 Parts Breakdown Description W1802 Parts ListPage Page Warranty and Returns Warranty Registration Woodstock International INC